ArticleMagnetic resonance imaging2024
POSE: POSition Encoding for accelerated quantitative MRI.
Article in Magnetic resonance imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- MC BTS: Simultaneously Resolving Magnetization Transfer Effect and Relaxation for Multiple Components.Magnetic resonance in medicine · 2026Article
- Simultaneous 3D quantitative magnetization transfer imaging and susceptibility mapping.Magnetic resonance in medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Quantitative MRI utilizes multiple acquisitions with varying sequence parameters to sufficiently characterize a biophysical model of interest, resulting in undesirable scan times. Here we propose, validate and demonstrate a new general strategy for accelerating MRI using subvoxel shifting as a source of encoding called POSition Encoding (POSE). The POSE framework applies unique subvoxel shifts along the acquisition parameter dimension, thereby creating an extra source of encoding. Combining with a biophysical signal model of interest, accelerated and enhanced resolution maps of biophysical parameters are obtained. This has been validated and demonstrated through numerical Bloch equation simulations, phantom experiments and in vivo experiments using the variable flip angle signal model in 3D acquisitions as an application example. Monte Carlo simulations were performed using in vivo data to investigate our method's noise performance. POSE quantification results from numerical Bloch equation simulations of both a numerical phantom and realistic digital brain phantom concur well with the reference method, validating our method both theoretically and for realistic situations. NIST phantom experiment results show excellent overall agreement with the reference method, confirming our method's applicability for a wide range of T
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.