ArticleSensors (Basel, Switzerland)2024
Design of MEMS Pressure Sensor Anti-Interference System Based on Filtering and PID Compensation.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- High-Precision MEMS Resonant Pressure Sensor for Real-Time Barometric Monitoring.Micromachines · 2026Article
- Design of a Rapid and Accurate Calibration System for Pressure Sensors with Minimized Temperature Variation.Sensors (Basel, Switzerland) · 2025Article
- Design and Hysteresis Compensation of Novel Resistive Angle Sensor Based on Rotary Potentiometer.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Due to the inherent temperature drift and lack of static stability in traditional pressure sensors, which make it difficult for them to meet the increasing demands of various industries, this paper designs a new system. The proposed system integrates temperature measurement and regulation circuits, signal processing, and communication circuits to accurately acquire and transmit pressure sensor data. The system designs a filtering algorithm to filter the original data and develops a data-fitting operation to achieve error compensation of the static characteristics. In order to eliminate the temperature drift problem of the sensor system, the system also adopts an improved PID thermostatic control algorithm to compensate for the temperature drift. Finally, it can also transmit the processed pressure data remotely. The experimental results show that the nonlinear error at 50 °C is reduced from the initial 1.82% to 0.24%; the hysteresis error is significantly reduced from 1.23% to 0.046%; and the repeatability error control is reduced from 3.79% to 0.89%. By compensating for thermal drift, the system's thermal sensitivity drift coefficient is reduced by 74.67%, the thermal zero drift coefficient is reduced by 66.24%, and the wireless communication range is up to 1km. The above significant optimization results fully validate the high accuracy and stability of the system, which is perfectly suited for demanding pressure measurement applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.