Evidence map›Paper›PMID 39275651›Full record

ArticleSensors (Basel, Switzerland)2024

Error Analysis and Optimization of Structural Parameters of Spatial Coordinate Testing System Based on Position-Sensitive Detector.

Haozhan Lu, Wenbo Chu, Bin Zhang, Donge Zhao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Haozhan LuCollege of Information and Communication Engineering, North University of China, Taiyuan 030000, China.
Wenbo ChuCollege of Mechatronic Engineering, North University of China, Taiyuan 030000, China.
Bin ZhangCollege of Information and Communication Engineering, North University of China, Taiyuan 030000, China.
Donge ZhaoCollege of Information and Communication Engineering, North University of China, Taiyuan 030000, China.

Funding

Fundamental Research Program of Shanxi Province 202203021212113National Natural Science Foundation of China 62205307
6 · The paper itself

Abstract

For the research on real-time accurate testing technology for the explosion point spatial coordinate of munitions, its currently commonly used methods such as acoustic-electric detection or high-speed imaging are limited by the field conditions, response rate, cost, and other factors. In this paper, a method of spatial coordinate testing for the explosion point based on a 2D PSD (position-sensitive detector) intersection is proposed, which has the advantages of a faster response, better real-time performance, and a lower cost. Firstly, a mathematical model of the spatial coordinate testing system was constructed, and an error propagation model for structural parameters was developed. The influence of the position of the optical axes' intersection as well as the azimuth angle and pitch angle on the test accuracy of the system was simulated and analyzed, thus obtaining the distribution and variation trend of the overall error propagation coefficient of the system. Finally, experiments were designed to obtain the test error of the system for validation. The results show that the system test accuracy is high when the azimuth angle is 20°-50°, the overall error propagation coefficient does not exceed 48.80, and the average test error is 56.17 mm. When the pitch angle is -2.5°-2.5°, the system has a higher test accuracy, with the overall error propagation coefficient not exceeding 44.82, and the average test error is 41.87 mm. The test accuracy of the system is higher when the position of the optical axes' intersection is chosen to make sure that explosion points fall in the region of the negative half-axis of the Zw-axis of the world coordinate system, with an overall error propagation coefficient of less than 44.78 and an average test error of 73.38 mm. It is shown that a reasonable selection of system structure parameters can significantly improve the system test accuracy and optimize the system deployment mode under the long-distance field conditions so as to improve the deployment efficiency.

Indexed as

position-sensitive detectorprecision analysisremote measurementspatial coordinate testingstructural parameters

Identifiers

PMID39275651
PMCPMC11398121

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.