Evidence map›Paper›PMID 39275597›Full record

ArticleSensors (Basel, Switzerland)2024

Optimal Sensor Placement for Enhanced Efficiency in Structural Health Monitoring of Medium-Rise Buildings.

Salman Saeed, Sikandar H Sajid, Luc Chouinard

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Salman SaeedNational Institute of Urban Infrastructure Planning, University of Engineering & Technology, Peshawar 25000, Pakistan.ORCID 0000-0001-7699-7714
Sikandar H SajidCivil Engineering, McGill University, Montreal, QC H3A 0C3, Canada.ORCID 0000-0001-8674-9538
Luc ChouinardCivil Engineering, McGill University, Montreal, QC H3A 0C3, Canada.

Funding

MSERC Discovery Grant
6 · The paper itself

Abstract

Output-only modal analysis using ambient vibration testing is ubiquitous for the monitoring of structural systems, especially for civil engineering structures such as buildings and bridges. Nonetheless, the instrumented nodes for large-scale structural systems need to cover a significant portion of the spatial volume of the test structure to obtain accurate global modal information. This requires considerable time and resources, which can be challenging in large-scale projects, such as the seismic vulnerability assessment over a large number of facilities. In many instances, a simple center-line (stairwell case) topology is generally used due to time, logistical, and economic constraints. The latter, though a fast technique, cannot provide complete modal information, especially for torsional modes. In this research, corner-line instrumented nodes layouts using only a reference and a roving sensor are proposed, which overcome this issue and can provide maximum modal information similar to that from 3D topologies for medium-rise buildings. Parametric studies are performed to identify the most appropriate locations for sensor placement at each floor of a medium-rise building. The results indicate that corner locations at each floor are optimal. The proposed procedure is validated through field experiments on two medium-rise buildings.

Indexed as

ambient vibration testinglarge-scale modal testingmodal analysistesting of medium-rise buildingtorsional mode

Identifiers

PMID39275597
PMCPMC11398206

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.