ArticleSensors (Basel, Switzerland)2024
Efficacy of PZT Sensors Network Different Configurations in Damage Detection of Fiber-Reinforced Concrete Prisms under Repeated Loading.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Article
- Research on the Defect Detection Method of Steel-Reinforced Concrete Based on Piezoelectric Technology and Weight Analysis.Sensors (Basel, Switzerland) · 2025Article
- Compressive Response and Damage Distribution of Fiber-Reinforced Concrete with Various Saturation Degrees.Materials (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Real-time structural health monitoring (SHM) and accurate diagnosis of imminent damage are critical to ensure the structural safety of conventional reinforced concrete (RC) and fiber-reinforced concrete (FRC) structures. Implementations of a piezoelectric lead zirconate titanate (PZT) sensor network in the critical areas of structural members can identify the damage level. This study uses a recently developed PZT-enabled Electro-Mechanical Impedance (EMI)-based, real-time, wireless, and portable SHM and damage detection system in prismatic specimens subjected to flexural repeated loading plain concrete (PC) and FRC. Furthermore, this research examined the efficacy of the proposed SHM methodology for FRC cracking identification of the specimens at various loading levels with different sensor layouts. Additionally, damage quantification using values of statistical damage indices is included. For this reason, the well-known conventional static metric of the Root Mean Square Deviation (RMSD) and the Mean Absolute Percentage Deviation (MAPD) were used and compared. This paper addresses a reliable monitoring experimental methodology in FRC to diagnose damage and predict the forthcoming flexural failure at early damage stages, such as at the onset of cracking. Test results indicated that damage assessment is successfully achieved using RMSD and MAPD indices of a strategically placed network of PZT sensors. Furthermore, the Upper Control Limit (UCL) index was adopted as a threshold for further sifting the scalar damage indices. Additionally, the proposed PZT-enable SHM method for prompt damage level is first established, providing the relationship between the voltage frequency response of the 32 PZT sensors and the crack propagation of the FRC prisms due to the step-by-step increased imposed load. In conclusion, damage diagnosis through continuous monitoring of PZTs responses of FRC due to flexural loading is a quantitative, reliable, and promising application.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.