Evidence map›Paper›PMID 39275538›Full record

ArticleSensors (Basel, Switzerland)2024

Magnetic Porous Hydrogel-Enhanced Wearable Patch Sensor for Sweat Zinc Ion Monitoring.

Yao Chu, Zhengzhong LvZeng, Kaijie Lu, Yangyang Chen, Yichuan Shen, Kejia Jing, Haifeng Yang, Wanxin Tang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yao ChuCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.
Zhengzhong LvZengCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.
Kaijie LuCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.
Yangyang ChenCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.
Yichuan ShenCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.
Kejia JingCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.
Haifeng YangCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.ORCID 0000-0003-3017-4215
Wanxin TangCollege of Chemistry and Materials Science, Shanghai Normal University, Shanghai 200234, China.

Funding

National Natural Science Foundation (NSF) of China No. 22304118S&TCSM of Shanghai No. 23YF1431000
6 · The paper itself

Abstract

Wearable sensors for sweat trace metal monitoring have the challenges of effective sweat collection and the real-time recording of detection signals. The existing detection technologies are implemented by generating enough sweat through exercise, which makes detecting trace metals in sweat cumbersome. Generally, it takes around 20 min to obtain enough sweat, resulting in dallied and prolonged detection signals that cannot reflect the endogenous fluctuations of the body. To solve these problems, we prepared a multifunctional hydrogel as an electrolyte and combined it with a flexible patch electrode to realize real-time monitoring of sweat Zn

Indexed as

HydrogelsSweatWearable Electronic DevicesZincBiosensing TechniquesFerrosoferric OxideHumansMagneticsFerrosoferric OxideHydrogelsZincfast sweat collectionmagnetic porous hydrogelnatural sweat detectionsweat trace metalsuniform distribution

Identifiers

PMID39275538
PMCPMC11398112

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.