Evidence map›Paper›PMID 39275533›Full record

ArticleSensors (Basel, Switzerland)2024

Design and Evaluation of a Novel Venturi-Based Spirometer for Home Respiratory Monitoring.

Mariana Ferreira Nunes, Hugo Plácido da Silva, Liliana Raposo, Fátima Rodrigues

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mariana Ferreira NunesDepartment of Bioengineering, Instituto Superior Técnico, University of Lisbon, 1949-001 Lisbon, Portugal.ORCID 0009-0005-7961-0729
Hugo Plácido da SilvaDepartment of Bioengineering, Instituto Superior Técnico, University of Lisbon, 1949-001 Lisbon, Portugal.ORCID 0000-0001-6764-8432
Liliana RaposoPulmonology Department, Santa Maria Local Health Unit, 1769-001 Lisbon, Portugal.
Fátima RodriguesPulmonology Department, Santa Maria Local Health Unit, 1769-001 Lisbon, Portugal.ORCID 0000-0002-4403-2878

Funding

Active Assisted Living Programme FORTO 2.0 (AAL/0006/2020)EU funds UIDB/50008/2020
6 · The paper itself

Abstract

The high cost and limited availability of home spirometers pose a significant barrier to effective respiratory disease management and monitoring. To address this challenge, this paper introduces a novel Venturi-based spirometer designed for home use, leveraging the Bernoulli principle. The device features a 3D-printed Venturi tube that narrows to create a pressure differential, which is measured by a differential pressure sensor and converted into airflow rate. The airflow is then integrated over time to calculate parameters such as the Forced Vital Capacity (FVC) and Forced Expiratory Volume in one second (FEV

Indexed as

Equipment DesignSpirometryAdultFemaleForced Expiratory VolumeHumansMaleMonitoring, PhysiologicReproducibility of ResultsRespiratory Function TestsVital CapacityBernoulli principlepressure sensorrespiration monitoringspirometryVenturi tube

Identifiers

PMID39275533
PMCPMC11398045

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked