ArticleSensors (Basel, Switzerland)2024
Development of Optical Sensors Based on Neutral Red Absorbance for Real-Time pH Measurements.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Novel delafossite structured visible-light sensitive AgFeOScientific reports · 2026Article
- Advancements in Optical Fiber Sensors for pH Measurement: Technologies and Applications.Sensors (Basel, Switzerland) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Measuring pH with an optical sensor requires the immobilization of a chemical recognition phase on a solid surface. Neutral red (NR), an acid base indicator was used to develop two different optical probe configurations. The chemistry of aryl diazonium salts was chosen for the elaboration of this chemical phase, as it enables strong covalent bonds to be established on the surface of metallized glass or metallic surfaces. It also allows the formation of a thick film required to obtain an exploitable spectral response. The surfaces of interest (metallized optical fiber and 316 L stainless-steel mirror) are modelized by flat surfaces (metallized glass plates and 316 L stainless-steel plates). The analytical characterizations carried out (IR, XPS, UV-Visible, and profilometry) show that NR was covalently grafted onto the model surfaces as well as on the surfaces of interest. The supports grafted with NR to develop optical pH probes exhibit spectral changes, particularly the values of pKa, the pH range, and the isosbestic point wavelength. The experimental results show that the optical probe can be used for pH measurements between 4 and 8.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.