Evidence map›Paper›PMID 39275481›Full record

ArticleSensors (Basel, Switzerland)2024

A Novel Shunt Zigzag Double-Tap Low-Harmonic Multi-Pulse Rectifier Based on a Three-Stage Power Electronic Phase-Shifting Transformer.

Xiuqing Mu, Xiaoqiang Chen, Qianxiao Liu, Ying Wang, Tun Bai, Leijiao Ge, Xiping Ma

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiuqing MuSchool of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Xiaoqiang ChenSchool of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Qianxiao LiuSchool of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Ying WangSchool of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Tun BaiSchool of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Leijiao GeSchool of Automation and Electrical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
Xiping MaState Grid Gansu Electric Power Company Electric Power Science Research Institute, Lanzhou 730070, China.

Funding

the National Natural Science Foundation of China; the Natural Science Key Foundation of Science and Technology Department of Gansu Province 52067013, 52367009; 21JR7RA280
6 · The paper itself

Abstract

To solve the problem of the large size of traditional industrial frequency phase-shift transformers and the harmonic distortion of multi-pulse wave rectifier systems, this paper proposes a three-stage shunt zigzag power electronic phase-shift transformer based on a double-tap multi-pulse wave rectifier, which combines the power factor correction (PFC) converter with the voltage-type SPWM inverter circuit to form a power electronic converter to realize the frequency boost and power factor correction. Through AC-DC-AC conversion, the frequency of the three-phase AC input voltage is increased, the number of core and coil turns in the transformer is reduced to reduce the size of the phase-shifter transformer, a zigzag structure of the phase-shifter transformer is used to solve the unbalanced distribution of current between the diode bridges, and a passive harmonic suppression method on the DC side is used to generate a loop current by using a group of single-phase rectifier bridges to regulate the input line current of the phase-shifter transformer. The phase-shifted voltage is input into two three-phase diode rectifier bridges to rectify and supply power to the load. Simulation and semi-physical test results show that the proposed method reduces the total harmonic distortion (THD) value of the input current of the phase-shifted transformer to 7.17%, and the THD value of the grid-side input current is further reduced to 2.49%, which meets the harmonic standard and realizes the purpose of power factor correction as well as being more suitable for high-power applications.

Indexed as

double-tapharmonic controlmulti-pulse rectificationpower factor correctionthree-stage power electronic phase-shifting transformer

Identifiers

PMID39275481
PMCPMC11398107

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.