Effect of Primary Cable Position on Accuracy in Non-Toroidal-Shaped Pass-Through Current Transformer.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Non-toroidal-shaped primary pass-through protection current transformers (CTs) are used to measure high currents. Their design provides them with a big airgap that allow the passing of several cables per phase though them, which is the main advantage versus toroidal types, as the number of CTs required to measure the whole phase current is drastically reduced. The cables passed through the transformer window can be in several positions. As the isolines of the magnetic field generated by the primary currents are centered in the cables, if these cables are not centered in the transformer window, then the magnetic field will be non-uniform along the transformer core. Consequently, local saturations can appear if the cables are not properly disposed, causing the malfunction of the CT. In this paper, the performance of a non-toroidal-shaped protection CT is studied. This research is focused on the influence of the cable position on possible partial saturations of the CT when it is operating near to its accuracy limit. Depending on the cable position, the ratio of the primary and secondary currents can depart from the assigned ratio. The validation of this phenomenon was carried out via finite element analysis (FEA), showing that partial transformer core saturations appear in areas of the magnetic core close to the cable. By applying FEA, the admissible accuracy region for cable positioning inside the CT is also delimited. Finally, the simulation results are ratified with experimental tests performed in non-toroidal protection CTs, varying the primary cables' positions, which are subjected to currents up to 5 kA, achieving satisfactory results. From this analysis, installation recommendations are given.