ArticleSensors (Basel, Switzerland)2024
Increasing the Beam Width and Intensity with Refraction Power Effect Using a Combination of Beam Mirrors and Concave Mirrors for Surgical-Fluorescence-Emission-Guided Cancer Monitoring Method.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Novel Fluorescence-Triggered Auditory Feedback Photosensor for Precision Lymph Node Mapping.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The primary goal during cancer removal surgery is to completely excise the malignant tumor. Because the color of the tumor and surrounding tissues is very similar, it is difficult to observe with the naked eye, posing a risk of damaging surrounding blood vessels during the tumor removal process. Therefore, fluorescence emission is induced using a fluorescent contrast agent, and color classification is monitored through camera imaging. LEDs must be irradiated to generate the fluorescent emission electromotive force. However, the power and beam width of the LED are insufficient to generate this force effectively, so the beam width and intensity must be increased to irradiate the entire lesion. Additionally, there should be no shaded areas in the beam irradiation range. This paper proposes a method to enhance the beam width and intensity while eliminating shadow areas. A total reflection beam mirror was used to increase beam width and intensity. However, when the beam width increased, a shadow area appeared at the edge, limiting irradiation of the entire lesion. To compensate for this shadow area, a concave lens was combined with the beam mirror, resulting in an increase in beam width and intensity by more than 1.42 times and 18.6 times, respectively. Consequently, the beam width reached 111.8°, and the beam power was 13.6 mW. The proposed method is expected to be useful for observing tumors through the induction of fluorescence emission during cancer removal surgery or for pathological examination in the pathology department.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.