Evidence map›Paper›PMID 39275414›Full record

ArticleSensors (Basel, Switzerland)2024

Increasing the Beam Width and Intensity with Refraction Power Effect Using a Combination of Beam Mirrors and Concave Mirrors for Surgical-Fluorescence-Emission-Guided Cancer Monitoring Method.

Jina Park, Jeongmin Seo, Kicheol Yoon, Sangyun Lee, Minchan Kim, Seung Yeob Ryu, Kwang Gi Kim

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jina ParkPremedicine Course & Department of Medicine, College of Medicine, Gachon University, Incheon 21565, Republic of Korea.
Jeongmin SeoPremedicine Course & Department of Medicine, College of Medicine, Gachon University, Incheon 21565, Republic of Korea.
Kicheol YoonPremedicine Course & Department of Medicine, College of Medicine, Gachon University, Incheon 21565, Republic of Korea.
Sangyun LeeDepartment of Radiological Science, Dongnam Health University, Suwon 16328, Republic of Korea.
Minchan KimMedical Devices R&D Center, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.
Seung Yeob RyuMedical Devices R&D Center, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.
Kwang Gi KimMedical Devices R&D Center, Gachon University Gil Medical Center, Incheon 21565, Republic of Korea.ORCID 0000-0001-9714-6038

Funding

GRRC program of Gyeonggi province GRRCGachon2023(B01)
6 · The paper itself

Abstract

The primary goal during cancer removal surgery is to completely excise the malignant tumor. Because the color of the tumor and surrounding tissues is very similar, it is difficult to observe with the naked eye, posing a risk of damaging surrounding blood vessels during the tumor removal process. Therefore, fluorescence emission is induced using a fluorescent contrast agent, and color classification is monitored through camera imaging. LEDs must be irradiated to generate the fluorescent emission electromotive force. However, the power and beam width of the LED are insufficient to generate this force effectively, so the beam width and intensity must be increased to irradiate the entire lesion. Additionally, there should be no shaded areas in the beam irradiation range. This paper proposes a method to enhance the beam width and intensity while eliminating shadow areas. A total reflection beam mirror was used to increase beam width and intensity. However, when the beam width increased, a shadow area appeared at the edge, limiting irradiation of the entire lesion. To compensate for this shadow area, a concave lens was combined with the beam mirror, resulting in an increase in beam width and intensity by more than 1.42 times and 18.6 times, respectively. Consequently, the beam width reached 111.8°, and the beam power was 13.6 mW. The proposed method is expected to be useful for observing tumors through the induction of fluorescence emission during cancer removal surgery or for pathological examination in the pathology department.

Indexed as

NeoplasmsFluorescenceHumansconcave lensfluorescence emissionLEDmirrorrefraction power

Identifiers

PMID39275414
PMCPMC11398251

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.