ArticleMolecules (Basel, Switzerland)2024
Exploiting the Applicability of Polytetrahydrofuran-Modified Polyester for the Fabric Phase Sorptive Extraction of Doxycycline from Human Urine.
Article in Molecules (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Development of a capsule phase microextraction (CPME) protocol for the determination of four tetracyclines in human urine prior to HPLC-DAD analysis.Analytical and bioanalytical chemistry · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this report, a polytetrahydrofuran-coated polyester fabric phase sorptive extraction (FPSE) for the determination of doxycycline in human urine was described. The sol-gel polytetrahydrofuran sorbent proved to be superior against other sol-gel coated cellulose and polyester membranes tested. The effect of the extraction parameters including membrane surface area, sample pH and volume, salt concentration, extraction time, stirring rate, etc., on the extraction efficiency of the analyte was studied using the "one-factor-at-a-time" (OFAT) and Box-Behnken design approaches. The analytical method proposed was validated in compliance with FDA guidelines for bioanalytical procedures. The method was linear in the determination range of 100-5000 ng/mL with the determination coefficient of 0.9953. The limit of detection (LOD) and the lower limit of quantification for doxycycline was 17 and 100 ng/mL, respectively. The relative recoveries for intra-day and inter-day studies ranged from 98.5-112.2% and 89.6-96.8%, respectively. The relative standard deviation was lower than 14.7% in all cases, exhibiting good precision. The sol-gel polytetrahydrofuran-modified FPSE membranes were reusable for at least 30 times. The greenness of the developed method was evaluated using Sample Preparation Metric of Sustainability (SPMS) and Blue Applicability Grade Index (BAGI) metric tools. Finally, the analytical scheme was successfully employed for the quantitation of urinary doxycycline collected at various time points following the administration of doxycycline-containing tablets.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.