ArticleMolecules (Basel, Switzerland)2024
A Spectral Detection Method Based on Integrated and Partition Modeling for Trace Copper in High-Concentration Zinc Solution.
Article in Molecules (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Integrating L-Cys-AuNCs in ZIF-8 with Enhanced Fluorescence and Strengthened Stability for Sensitive Detection of Copper Ions.Molecules (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
In zinc smelting solution, because the concentration of zinc is too high, the spectral signals of trace copper are masked by the spectral signals of zinc, and their spectral signals overlap, which makes it difficult to detect the concentration of trace copper. To solve this problem, a spectrophotometric method based on integrated and partition modeling is proposed. Firstly, the derivative spectra based on continuous wavelet transform are used to preprocess the spectral signal and highlight the spectral peak of copper. Then, the interval partition modeling is used to select the optimal characteristic interval of copper according to the root mean square error of prediction, and the wavelength points of the absorbance matrix are selected by correlation-coefficient threshold to improve the sensitivity and linearity of copper ions. Finally, the partial least squares integrated modeling based on the Adaboost algorithm is established by using the selected wavelength to realize the concentration detection of trace copper in the zinc liquid. Comparing the proposed method with existing regression methods, the results showed that this method can not only reduce the complexity of wavelength screening, but can also ensure the stability of detection performance. The predicted root mean square error of copper was 0.0307, the correlation coefficient was 0.9978, and the average relative error of prediction was 3.14%, which effectively realized the detection of trace copper under the background of high-concentration zinc liquid.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.