Optical Methods for Optimizing Fluorescence Imaging Field of View and Image Quality in Surgical Guidance Procedures.

Jeongmin Seo, Jina Park, Kicheol Yoon, Sangyun Lee, Minchan Kim, Seung Yeob Ryu, Kwang Gi Kim

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jeongmin SeoPremedicine Course & Department of Medicine, College of Medicine, Gachon University, 8-13, 3 Dokjom-ro, Namdong-gu, Incheon 21565, Republic of Korea.
Jina ParkPremedicine Course & Department of Medicine, College of Medicine, Gachon University, 8-13, 3 Dokjom-ro, Namdong-gu, Incheon 21565, Republic of Korea.
Kicheol YoonPremedicine Course & Department of Medicine, College of Medicine, Gachon University, 8-13, 3 Dokjom-ro, Namdong-gu, Incheon 21565, Republic of Korea.
Sangyun LeeDepartment of Radiological Science, Dongnam Health University, 50 Cheoncheon-ro 74 gil Jangan-gu, Suwon 16328, Republic of Korea.ORCID 0009-0008-7062-1116
Minchan KimMedical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.
Seung Yeob RyuMedical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.
Kwang Gi KimMedical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.ORCID 0000-0001-9714-6038

Funding

GRRC program of Gyeonggi province GRRCGachon2023(B01)
6 · The paper itself

Abstract

Cancer surgery is aimed at complete tumor resection and accurate lymph node detection. However, numerous blood vessels are distributed within the tumor, and the colors of the tumor, blood vessels, and lymph nodes are similar, making observations with the naked eye difficult. Therefore, tumors, blood vessels, and lymph nodes can be monitored via color classification using an operating microscope to induce fluorescence emission. However, as the beam width of the LED required to induce fluorescence emission is narrow and the power loss of the beam is significant at a certain working distance, there are limitations to inducing fluorescence emission, and light reflection occurs in the observation image, obstructing the view of the observation area. Therefore, the removal of reflected light is essential to avoid missing the diagnosis of the lesion under observation. This paper proposes the use of a beam mirror and polarizing filter to increase the beam width and beam intensity. The refraction and reflection effects of the beam were utilized using the beam mirror, and the rotation angle of the polarizing filter was adjusted to remove light reflection. Consequently, the minimum beam power using the beam mirror was 10.9 mW, the beam width was doubled to 40.2°, and more than 98% of light reflection was removed at 90° and 270°. With light reflection effectively eliminated, clear observation of lesions is possible. This method is expected to be used effectively in surgical, procedural, and diagnostic departments.

Indexed as

beam mirrorfluorescence emissionLEDlight reflection removallinear polarized filter

Identifiers

PMID39272780
PMCPMC11393884

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.