Evidence map›Paper›PMID 39272090›Full record

ArticleBMC oral health2024

The wettability of complete denture base materials constructed by conventional versus digital techniques: an in-vitro study.

Kenda I Hanno, Nayrouz Adel Metwally

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Kenda I HannoDepartment of Prosthodontics, Faculty of Dentistry, University of Alexandria, Champolion St, Alexandria, Egypt.
Nayrouz Adel MetwallyDepartment of Prosthodontics, Faculty of Dentistry, University of Alexandria, Champolion St, Alexandria, Egypt. nayrouz.metwally@alexu.edu.eg.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDecreased salivary flow can make the patients uncomfortable with their complete dentures and affects the retention of the dentures. Milling and 3D printing have become an alternative to conventional denture construction techniques. The goal of this study was to evaluate the effect of conventional and digital techniques of the complete denture construction on the denture surface wettability with distilled water and saliva substitute before and after thermocycling.

methodsA total of 30 specimens were utilized in the present study. Specimens were divided according to the construction techniques into 3 groups (n = 10 each). Group I: Heat-polymerized polymethylmethacrylate (PMMA) group, group II: Milled group, and group III: 3-dimensional (3D)-printed group. All the specimens were subjected to 2000 cycles of thermal aging in a thermocycler. The wettability of all specimens to water and saliva substitute was measured via a contact angle goniometer (Olympus TGHM, Rame-hart Inc, USA) before and after thermocycling. Descriptive statistical analysis, plots, and the Shapiro-Wilk test were used to verify normality for each variable. One-way ANOVA was used to compare the 3 study groups, while paired samples t-test was used to compare the differences within each group (P < .05).

resultsThe smallest contact angle of drop of water to the denture base specimens before and after thermocycling were recorded in the milled group (53.0 ± 4.77 and 50.27 ± 2.30, respectively), followed by the heat polymerized PMMA group (85.65 ± 4.71 and 65.06 ± 2.27, respectively), and the 3D-printed group (91.34 ± 6.74 and 90.86 ± 8.57, respectively). While the smallest contact angle of drop of saliva substitute to denture base specimens was recorded in the milled group (56.82 ± 2.29 and 34.85 ± 7.51, respectively), followed by the 3D-printed group (72.87 ± 4.83 and 58.14 ± 9.58, respectively) and the heat polymerized PMMA group (83.62 ± 4.12 and 67.82 ± 4.93, respectively). There was statistically significant difference between the groups (P < .05). A significant decline in the average contact angle of drop of saliva has been reported in all groups after thermocycling. The contact angle values differed significantly between saliva substitute and distilled water in both 3D-printed and milled groups after thermocycling (P < .001).

conclusionsThe milled denture base material presented the best wettability to water and saliva substitute than the 3D-printed and the heat-polymerized PMMA materials. Saliva substitutes improve the wetting ability of denture base materials manufactured by CAD/CAM compared with water.

Indexed as

Denture BasesDenture, CompletePolymethyl MethacrylatePrinting, Three-DimensionalWettabilityComputer-Aided DesignDental MaterialsDenture DesignHumansIn Vitro TechniquesMaterials TestingSurface PropertiesWaterDental MaterialsPolymethyl MethacrylateWater3D-printedCAD-CAMContact angleHeat-polymerizedWettability

Identifiers

PMID39272090
PMCPMC11395271

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.