Evidence map›Paper›PMID 39271510›Full record

ArticleSurgical endoscopy2024

One year follow-up of the colon cancer patient cohort treated with a novel miniaturized robotic-assisted surgery device (mRASD).

John H Marks, Michael A Jobst, Deborah S Keller, Jorge A Lagares-Garcia, Henry P Schoonyoung, Shane M Farritor, Dmitry Oleynikov

Abstract readMulticenter Study
In one paragraph

Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

John H MarksLankenau Medical Center and Lankenau Institute for Medical Research, Wynnewood, PA, USA.
Michael A JobstBryan Medical Center, Surgical Associates P.C, 1001 S. 70th, Ste. 100, Lincoln, NE, 68510, USA. mjobst@neb.rr.com.
Deborah S KellerLankenau Medical Center and Lankenau Institute for Medical Research, Wynnewood, PA, USA.
Jorge A Lagares-GarciaRoper St Francis Health Alliance, Charleston, SC, USA.
Henry P SchoonyoungLankenau Medical Center, Wynnewood, PA, USA.
Shane M FarritorDepartment of Mechanical Engineering, University of Nebraska, Lincoln, NE, USA.
Dmitry OleynikovMonmouth Medical Center Robert Wood Johnson and Barnabas Health, Long Branch, NJ, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWith the proven benefits of minimally invasive surgery, there is steady growth in robotic surgery use and interest in novel robotic platforms. A miniaturized Robotic-Assisted Surgery Device (mRASD) has been in clinical use under a multi-center, investigational device exemption (IDE) study for right and left colectomy. The goal of this work was to report the short-term and 12-month outcomes specifically for the cohort of colon cancer patients that underwent surgery using the mRASD.

methodFrom the IDE study that included both benign and malignant diseases, long-term follow-up was only conducted for patients with colon cancer. The main outcome measures were the oncologic quality metrics (Overall Survival, OS and Disease-free Survival, DFS). Secondary outcomes included incidence of intra-operative, device-related, and procedure-related adverse events. Frequency statistics were performed to assess the measures of central tendency and variability in short (within 30 days) and long-term (1-year) outcomes.

resultsThirty total patients underwent a colectomy with mRASD; 17 (57%) were diagnosed with a malignancy and included in this analysis. The mean patient age was 59.9 ± 13.2 years. There were no intraoperative or device-related adverse events. In 100% of cases (n = 17), the primary dissection was completed and hemostasis maintained using the mRASD, and negative margins were achieved. At 30 days postoperatively, the major complication rate was 6%, and there was one unplanned reoperation for anastomotic leak. At one-year follow-up, the OS and DFS rates were 100 and 94%, respectively. In one patient, omental implants were discovered at the time of surgery, and the patient opted to not undergo additional therapy.

conclusionsThe first experience with mRASD for colectomy in colon cancer demonstrated technical effectiveness and an acceptable surgical safety profile in line with other minimally invasive procedures. The study continues to monitor disease recurrence and survival outcomes in this cohort.

Indexed as

ColectomyColonic NeoplasmsRobotic Surgical ProceduresAdultAgedAged, 80 and overDisease-Free SurvivalFemaleFollow-Up StudiesHumansMaleMiddle AgedMiniaturizationPostoperative ComplicationsTreatment OutcomeColon cancerColorectal cancerRobotic colorectal surgeryRobotic surgery

Identifiers

PMID39271510
PMCPMC11615019

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.