Evidence map›Paper›PMID 39271494›Full record

ReviewArchives of orthopaedic and trauma surgery2024

The infraacetabular screw - anatomy, radiology, biomechanics and clinics.

Axel Gänsslen, Jan Lindahl, Richard A Lindtner, Dietmar Krappinger

Abstract readReview
In one paragraph

Review in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Axel GänsslenTrauma Department, Hannover Medical School, Hanover, Germany.
Jan LindahlDepartment of Orthopaedics and Traumatology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
Richard A LindtnerDepartment of Orthopaedic and Trauma Surgery, Medical University Innsbruck, Anichstraße 35, Innsbruck, 6020, Austria.
Dietmar KrappingerDepartment of Orthopaedic and Trauma Surgery, Medical University Innsbruck, Anichstraße 35, Innsbruck, 6020, Austria. dietmar@krappinger.eu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acetabular fracture surgery follows the primary aim of anatomic reduction and rigid stable fixation of the fracture. Infraacetabular screws (IAS) allow for an increased stability of the acetabular fixation by closing the periacetabular fixation frame without requiring an additional posterior approach. The osseous screw corridor for infraacetabular screws use the transition zone between the acetabular ring and the obturator ring. The infraacetabular screw corridor (IAC) shows a double-cone shape with an isthmus located near the acetabular fovea. The iliopectineal eminence (IE) is mainly used as a clinical landmark for the intraoperative assessment of the entry point of IAS. The inlet view, the combined obturator oblique outlet view and a 1/3 iliac oblique outlet view may be used for the intraoperative radiological assessment for both the entry point and the screw trajectory of IAS. Several biomechanical studies have shown that IAS increase the stiffness of the internal fixation. Scientific proof for an improved clinical outcome is still missing.

Indexed as

AcetabulumBone ScrewsFracture Fixation, InternalFractures, BoneBiomechanical PhenomenaHumansAcetabular fractureAnatomyBiomechanicsInfraacetabular screwRadiology