Evidence map›Paper›PMID 39268932›Full record

ArticleActa orthopaedica2024

Measuring total hip arthroplasty liner wear using the EOS Imaging System: experimental and clinical results.

Kristian Kjærgaard, Sibel Yilmaz, Bart Kaptein, Søren Overgaard, Ming Ding

Abstract read
In one paragraph

Article in Acta orthopaedica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kristian KjærgaardOrthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark kristian.kjaergaard@rsyd.dk.ORCID 0000-0002-0859-3627
Sibel YilmazOrthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.
Bart KapteinBiomechanics and Imaging Group, Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands.ORCID 0000-0001-8772-9985
Søren OvergaardOrthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense; Department of Clinical Research, University of Southern Denmark, Odense; Copenhagen University Hospital, Bispebjerg Department of Orthopaedic Surgery and Traumatology, Frederiksberg Hospital, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.ORCID 0000-0001-6829-4787
Ming DingOrthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeThe low-dose EOS Imaging System is an emerging tool for 3-dimensional measurements in orthopedics. The clinical feasibility for measuring total hip arthroplasty (THA) liner wear has not yet been investigated. We aimed to evaluate the feasibility of using EOS to measure THA liner wear by examining the experimental accuracy using a THA phantom and clinical precision of patients with THA, considering a clinically relevant precision at the 95% repeatability limit to be 0.2 mm.

methodsAn experimental THA phantom with movable stem and a fixed cup with a plastic liner was constructed to simulate progressive 3D liner wear. Series of 11 pairs of radiographs with 50 μm femoral movement in between were obtained for each 3D axis in EOS. 30 patients with a THA were scanned twice using EOS to assess precision. Model-based radiostereometric analysis (RSA) was used for wear measurement.

resultsThe mean difference (true minus simulated wear) with standard deviation (SD) and 95% limits of agreement for experimental THA wear were 0.005 (0.037) and [-0.069 to 0.079] mm for the vertical (y) axis. The mean (SD) and 95% repeatability limit for precision for clinical measurement were -0.029 (0.105) and 0.218 mm.

conclusionExperimental THA liner wear using EOS was within clinically relevant tolerances and without bias. The clinical precision was just outside our defined clinically relevant precision. Compared with conventional RSA, EOS is less accurate and precise but may still be of value for certain clinical applications, provided larger sample size or longer follow-up are available.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisPhantoms, ImagingAgedFeasibility StudiesFemaleHumansImaging, Three-DimensionalMaleMiddle AgedProsthesis FailureRadiostereometric AnalysisReproducibility of Results

Identifiers

PMID39268932
PMCPMC11395818

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.