Evidence map›Paper›PMID 39266784›Full record

ArticleEuropean radiology experimental2024

Training and validation of a deep learning U-net architecture general model for automated segmentation of inner ear from CT.

Jonathan Lim, Aurore Abily, Douraïed Ben Salem, Loïc Gaillandre, Arnaud Attye, Julien Ognard

Abstract readValidation StudyMulticenter Study
In one paragraph

Article in European radiology experimental, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jonathan LimDepartment of Neuroradiology-Brest University Hospital, Boulevard Tanguy Prigent, 29200, Brest, France. jonathan.lim.radiopro@gmail.com.ORCID http://orcid.org/0009-0002-3653-922X
Aurore AbilyDepartment of Neuroradiology-Brest University Hospital, Boulevard Tanguy Prigent, 29200, Brest, France.
Douraïed Ben SalemDepartment of Neuroradiology-Brest University Hospital, Boulevard Tanguy Prigent, 29200, Brest, France.
Loïc GaillandreCLIMAL, 26 Rue du Ballon, 59000, Lille, France.
Arnaud AttyeGeodAIsics, Biopolis, 38043, Grenoble, France.
Julien OgnardDepartment of Neuroradiology-Brest University Hospital, Boulevard Tanguy Prigent, 29200, Brest, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe intricate three-dimensional anatomy of the inner ear presents significant challenges in diagnostic procedures and critical surgical interventions. Recent advancements in deep learning (DL), particularly convolutional neural networks (CNN), have shown promise for segmenting specific structures in medical imaging. This study aimed to train and externally validate an open-source U-net DL general model for automated segmentation of the inner ear from computed tomography (CT) scans, using quantitative and qualitative assessments.

methodsIn this multicenter study, we retrospectively collected a dataset of 271 CT scans to train an open-source U-net CNN model. An external set of 70 CT scans was used to evaluate the performance of the trained model. The model's efficacy was quantitatively assessed using the Dice similarity coefficient (DSC) and qualitatively assessed using a 4-level Likert score. For comparative analysis, manual segmentation served as the reference standard, with assessments made on both training and validation datasets, as well as stratified analysis of normal and pathological subgroups.

resultsThe optimized model yielded a mean DSC of 0.83 and achieved a Likert score of 1 in 42% of the cases, in conjunction with a significantly reduced processing time. Nevertheless, 27% of the patients received an indeterminate Likert score of 4. Overall, the mean DSCs were notably higher in the validation dataset than in the training dataset.

conclusionThis study supports the external validation of an open-source U-net model for the automated segmentation of the inner ear from CT scans. RELEVANCE STATEMENT: This study optimized and assessed an open-source general deep learning model for automated segmentation of the inner ear using temporal CT scans, offering perspectives for application in clinical routine. The model weights, study datasets, and baseline model are worldwide accessible. KEY POINTS: A general open-source deep learning model was trained for CT automated inner ear segmentation. The Dice similarity coefficient was 0.83 and a Likert score of 1 was attributed to 42% of automated segmentations. The influence of scanning protocols on the model performances remains to be assessed.

Indexed as

Deep LearningEar, InnerTomography, X-Ray ComputedAdultAgedFemaleHumansMaleMiddle AgedNeural Networks, ComputerRetrospective StudiesArtificial intelligenceEar (inner)Image processing (computer-assisted)Neural networks (computer)Tomography (x-ray computed)

Identifiers

PMID39266784
PMCPMC11393264

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.