Evaluation of forces applied to tissues during robotic-assisted surgical tasks using a novel force feedback technology.

Michael M Awad, Mathew C Raynor, Mika Padmanabhan-Kabana, Lana Y Schumacher, Jeffrey A Blatnik

Abstract read
In one paragraph

Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Article
  9. Article
  10. Soft, Flexible, and Stretchable Platforms for Tissue-Interfaced Bioelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Design and Performance of a Neurosurgery Assisting Device.Biomimetics (Basel, Switzerland) · 2025
    Article
  17. Article
  18. Review
  19. Minimally Invasive Donor Hepatectomy.Journal of clinical and experimental hepatology
    Review
  20. Safety of Continuous Force Feedback in Robotic Hysterectomy and Myomectomy.JSLS : Journal of the Society of Laparoendoscopic Surgeons
    Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Michael M AwadDepartment of Surgery, Washington University School of Medicine, St. Louis, MO, USA. awadm@wustl.edu.ORCID 0000-0002-6065-7050
Mathew C RaynorDepartment of Urology, School of Medicine, University of North Carolina, Chapel Hill, NC, USA.
Mika Padmanabhan-KabanaIntuitive Surgical, Sunnyvale, USA.
Lana Y SchumacherDivision of Thoracic Surgery, Tufts Medical School, Boston, MA, USA.
Jeffrey A BlatnikDepartment of Surgery, Washington University School of Medicine, St. Louis, MO, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe absence of force feedback (FFB) is considered a technical limitation in robotic-assisted surgery (RAS). This pre-clinical study aims to evaluate the forces applied to tissues using a novel integrated FFB technology, which allows surgeons to sense forces exerted at the instrument tips.

methodsTwenty-eight surgeons with varying experience levels employed FFB instruments to perform three robotic-assisted surgical tasks, including retraction, dissection, and suturing, on inanimate or ex-vivo models, while the instrument sensors recorded and conveyed the applied forces to the surgeon hand controllers of the robotic system. Generalized Estimating Equations (GEE) models were used to analyze the mean and maximal forces applied during each task with the FFB sensor at the "Off" setting compared to the "High" sensitivity setting for retraction and to the "Low", "Medium", and "High" sensitivity settings for dissection and suturing. Sub-analysis was also performed on surgeon experience levels.

resultsThe use of FFB at any of the sensitivity settings resulted in a significant reduction in both the mean and maximal forces exerted on tissue during all three robotic-assisted surgical tasks (p < 0.0001). The maximal force exerted, potentially associated with tissue damage, was decreased by 36%, 41%, and 55% with the use of FFB at the "High" sensitivity setting while performing retraction, dissection, and interrupted suturing tasks, respectively. Further, the use of FFB resulted in substantial reductions in force variance during the performance of all three types of tasks. In general, reductions in mean and maximal forces were observed among surgeons at all experience levels. The degree of force reduction depends on the sensitivity setting selected and the types of surgical tasks evaluated.

conclusionsOur findings demonstrate that the utilization of FFB technology integrated in the robotic surgical system significantly reduced the forces exerted on tissue during the performance of surgical tasks at all surgeon experience levels. The reduction in the force applied and a consistency of force application achieved with FFB use, could result in decreases in tissue trauma and blood loss, potentially leading to better clinical outcomes in patients undergoing RAS. Future studies will be important to determine the impact of FFB instruments in a live clinical environment.

Indexed as

Robotic Surgical ProceduresAnimalsClinical CompetenceDissectionFeedbackHumansSuture TechniquesEx-vivo tissueForce feedbackHaptic technologyInanimate modelRobotic-assisted surgery

Identifiers

PMID39266755
PMCPMC11458697

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.