Evidence map›Paper›PMID 39265820›Full record

ArticleJournal of neuroscience methods2024

Optimizing magnetometers arrays and analysis pipelines for multivariate pattern analysis.

Yulia Bezsudnova, Andrew J Quinn, Ole Jensen

Abstract read
In one paragraph

Article in Journal of neuroscience methods, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Enhanced Neural Decoding With Optically Pumped Magnetometer MEG Using Multivariate Pattern Analysis.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
  2. Anatomically Veridical On-Scalp Sensor Topographies.The European journal of neuroscience · 2025
    Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yulia BezsudnovaCentre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, UK. Electronic address: y.bezsudnova@bham.ac.uk.
Andrew J QuinnCentre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, UK.
Ole JensenCentre for Human Brain Health, School of Psychology, University of Birmingham, Birmingham, UK.

Funding

Biotechnology and Biological Sciences Research Council BB/R018723/1Wellcome Trust 207550Wellcome Trust EP/T001046/1
6 · The paper itself

Abstract

backgroundMultivariate pattern analysis (MVPA) has proven an excellent tool in cognitive neuroscience. It also holds a strong promise when applied to optically-pumped magnetometer-based magnetoencephalography. NEW

methodTo optimize OPM-MEG systems for MVPA experiments this study examines data from a conventional MEG magnetometer array, focusing on appropriate noise reduction techniques for magnetometers. We determined the least required number of sensors needed for robust MVPA for image categorization experiments.

resultsWe found that the use of signal space separation (SSS) without a proper regularization significantly lowered the classification accuracy considering a sub-array of 102 magnetometers or a sub-array of 204 gradiometers. We also found that classification accuracy did not improve when going beyond 30 sensors irrespective of whether SSS has been applied. COMPARISON WITH EXISTING

methodsThe power spectra of data filtered with SSS has a substantially higher noise floor that data cleaned with SSP or HFC. Consequently, MVPA decoding results obtained from the SSS-filtered data are significantly lower compared to all other methods employed.

conclusionsWhen designing MEG system based on SQUID magnetometers optimized for multivariate analysis for image categorization experiments, about 30 magnetometers are sufficient. We advise against applying SSS filters without a proper regularization to data from MEG and OPM systems prior to performing MVPA as this method, albeit reducing low-frequency external noise contributions, also introduces an increase in broadband noise. We recommend employing noise reduction techniques that either decrease or maintain the noise floor of the data like signal-space projection, homogeneous field correction and gradient noise reduction.

Indexed as

MagnetoencephalographyAdultBrainBrain MappingFemaleHumansMaleMultivariate AnalysisSignal Processing, Computer-AssistedYoung AdultGradiometersMagnetoencephalographyMagnetometersMVPAOptically pumped magnetometersOptimizationSignal space separation filter

Identifiers

PMID39265820
PMCPMC7619272

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked