Evidence map›Paper›PMID 39265559›Full record

ArticleActa cytologica2024

Fine-Needle Aspiration versus the CytoCore® Motorized Rotating Needle Device for Thyroid Nodule Biopsies: A Retrospective Cohort Study.

Adarsh Verma, Rhonda McDowell, Anthony Porreca

Abstract readComparative Study
In one paragraph

Article in Acta cytologica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Adarsh VermaDivision of Interventional Radiology, Department of Radiology, Morton Plant Mease Hospital, BayCare Health System, Clearwater, Florida, USA.
Rhonda McDowellDivision of Interventional Radiology, Department of Radiology, Morton Plant Mease Hospital, BayCare Health System, Clearwater, Florida, USA.
Anthony PorrecaDivision of Interventional Radiology, Department of Radiology, Morton Plant Mease Hospital, BayCare Health System, Clearwater, Florida, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionRecently, an FDA cleared motorized fine-needle aspiration device (CytoCore®, Praxis Medical) has become available which is designed to reduce sample variability by enabling more consistent sampling due to the rotational drilling action of the device in combination with the standard in and out motion used to access the thyroid nodule with a needle. The rotation of the needle permits the ability to collect a higher quantity of intact cellular material, which is optimal for determining adequacy and, ultimately, for making a diagnosis. The present study compares the diagnostic performance of a motorized fine needle aspiration (FNA) device to a historical cohort of patients biopsied using ultrasound-guided fine needle aspiration (US-FNA).

methodsData from 120 patients with thyroid nodules biopsied using a motorized FNA device was retrospectively analyzed. Patient demographics, lesion characteristics, number of passes, Bethesda category, and cellularity scores were compared to a historical control cohort of 100 patients who underwent US-FNA. Nondiagnostic and indeterminate samples rates for motorized FNA were separately compared to literature controls.

resultsA significantly reduced median number of passes were required with motorized FNA compared to US-FNA (1.48 ± 0.62 vs. 2.64 ± 1.63, p < 0.001). Adequate samples were obtained after the first pass for 58% of biopsies with motorized FNA compared to 11% with US-FNA. The cumulative percentage of adequate samples increased to 98% after two passes for motorized FNA versus 58% for the US-FNA group. The mean cellularity score was also significantly greater for motorized FNA (3.42 ± 0.63 vs. 1.9 ± 0.59; p < 0.001). A determinant diagnosis was possible for a greater number of samples in the motorized FNA group compared to the control group (91.6% vs. 78%; p = 0.05). The motorized FNA also had a lower nondiagnostic rate compared to US-FNA (2.0% vs. 10%) and a lower indeterminate rate compared to published rates associated with the use of FNA (8.3% vs. 20.0%; p = 0.05).

conclusionThe motorized FNA device required less passes to obtain an adequate biopsy than US-FNA. Its use is also associated with obtaining samples with a higher cellularity and lower nondiagnostic and indeterminate sample rates.

Indexed as

Thyroid NoduleAdultAgedAged, 80 and overBiopsy, Fine-NeedleEquipment DesignFemaleHumansMaleMiddle AgedNeedlesPredictive Value of TestsRetrospective StudiesThyroid GlandUltrasonography, InterventionalBiopsyFine-needle aspirationIndeterminateNondiagnosticThyroid

Identifiers

PMID39265559
PMCPMC11548101

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.