Performance evaluation of a 4D similarity filter for dynamic CT angiography imaging of the liver.

Sjoerd A M Tunissen, Ewoud J Smit, Mikhail Mikerov, Mathias Prokop, Ioannis Sechopoulos

Abstract readEvaluation Study
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sjoerd A M TunissenDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Ewoud J SmitDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Mikhail MikerovDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Mathias ProkopDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Ioannis SechopoulosDepartment of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDynamic computed tomography (CT) angiography of the abdomen provides perfusion information and characteristics of the tissues present in the abdomen. This information could potentially help characterize liver metastases. However, radiation dose has to be relatively low for the patient, causing the images to have very high noise content. Denoising methods are needed to increase image quality. PURPOSE: The purpose of this study was to investigate the performance, limitations, and behavior of a new 4D filtering method, called the 4D Similarity Filter (4DSF), to reduce image noise in temporal CT data.

methodsThe 4DSF averages voxels with similar time-intensity curves (TICs). Each phase is filtered individually using the information of all phases except for the one being filtered. This approach minimizes the bias toward the noise initially present in this phase. Since the 4DSF does not base similarity on spatial proximity, loss of spatial resolution is avoided. The 4DSF was evaluated on a 12-phase liver dynamic CT angiography acquisition of 52 digital anthropomorphic phantoms, each containing one hypervascular 1 cm lesion with a small necrotic core. The metrics used for evaluation were noise reduction, lesion contrast-to-noise ratio (CNR), CT number accuracy using peak-time and peak-intensity of the TICs, and resolution loss. The results were compared to those obtained by the time-intensity profile similarity (TIPS) filter, which uses the whole TIC for determining similarity, and the combination 4DSF followed by TIPS filter (4DSF + TIPS).

resultsThe 4DSF alone resulted in a median noise reduction by a factor of 6.8, which is lower than that obtained by the TIPS filter at 8.1, and 4DSF + TIPS at 12.2. The 4DSF increased the median CNR from 0. 44 to 1.85, which is less than the TIPS filter at 2.59 and 4DSF + TIPS at 3.12. However, the peak-intensity accuracy in the TICs was superior for the 4DSF, with a median intensity decrease of -34 HU compared to -88 and -50 HU for the hepatic artery when using the TIPS filter and 4DSF + TIPS, respectively. The median peak-time accuracy was inferior for the 4DSF filter and 4DSF + TIPS, with a time shift of -1 phases for the portal vein TIC compared to no shift in time when using the TIPS. The analysis of the full-width-at-half-maximum (FWHM) of a small artery showed significantly less spatial resolution loss for the 4DSF at 3.2 pixels, compared to the TIPS filter at 4.3 pixels, and 3.4 pixels for the 4DSF + TIPS.

conclusionThe 4DSF can reduce noise with almost no resolution loss, making the filter very suitable for denoising 4D CT data for detection tasks, even in very low dose, i.e., very high noise level, situations. In combination with the TIPS filter, the noise reduction can be increased even further.

Indexed as

Computed Tomography AngiographyLiverPhantoms, ImagingSignal-To-Noise RatioAlgorithmsFour-Dimensional Computed TomographyHumansImage Processing, Computer-AssistedCT perfusiondenoisinglesion detectionlow‐dose CT

Identifiers

PMID39264288
PMCPMC11656287

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.