ArticleCardiovascular diagnosis and therapy2024
Computer simulation help predict the frame deformation following a Venus-A transcatheter aortic valve implantation in patients with pure aortic regurgitation: a retrospective study.
Article in Cardiovascular diagnosis and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 synthesis or guideline pooled it.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Patient-specific computer simulation of transcatheter aortic valve implantation (TAVI) predicts the interaction between an implanted device and the surrounding anatomy. In this study, we validated the predictive value of computer simulation for the frame deformation following a Venus-A TAVI implant in patients with pure aortic regurgitation (AR). Furthermore, we used the validated computational model to evaluate the anchoring mechanism within the same cohort. Methods: This was a retrospective study. FEops HEARTguide technology was used to simulate the virtual implantation of a Venus-A valve model in a patient-specific geometry. The predicted frame deformation was quantitatively compared to the postoperative device deformation at multiple levels. The outward forces acting on the frame were extracted for each patient and the total outward force acting around the aortic annular (AA) and sinotubular junction (STJ) planes were recorded. Results: Thirty patients were enrolled in the study with 10 in the migration group and 20 in the non-migration group. The dimensions of the simulated and observed frames had good correlations at Dmax (R Conclusions: Patient-specific computer simulation of TAVI accurately predicted frame deformation in Chinese patients with pure AR. The forces at the STJ facilitated stabilization of the device within the aortic root, which might be used as a discriminator to identify patients at risk of device migration prior to intervention.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.