Evidence map›Paper›PMID 39262946›Full record

ArticleHeliyon2024

Evaluation of flow cytometry-based fluorescent antibody to membrane antigen test to measure the humoral immunity against the varicella-zoster virus.

Junmo Lim, Yunhwa Kim, Ji Young Hwang, Kyung Min Lee, Hosun Park

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Junmo LimDepartment of Microbiology, College of Medicine, Yeungnam University, Daegu, 42415, Republic of Korea.
Yunhwa KimDepartment of Microbiology, College of Medicine, Yeungnam University, Daegu, 42415, Republic of Korea.
Ji Young HwangDepartment of Microbiology, College of Medicine, Yeungnam University, Daegu, 42415, Republic of Korea.
Kyung Min LeeDepartment of Microbiology, College of Medicine, Yeungnam University, Daegu, 42415, Republic of Korea.
Hosun ParkDepartment of Microbiology, College of Medicine, Yeungnam University, Daegu, 42415, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The fluorescent antibody to membrane antigen (FAMA) test is the gold standard for measuring the immunity induced by varicella vaccines with high sensitivity and specificity. However, certain aspects of the FAMA test, such as time consumption, non-automation, and subjective interpretation by observers using fluorescence microscopy, are obstacles to handling large amounts of samples. To overcome these hurdles, flow cytometry was adopted to analyze and compare the flow FAMA titer with the classic FAMA titer. In addition, to save time in FAMA antigen preparation and reduce lot-to-lot variation, the stability of the FAMA antigen stored in liquid nitrogen was investigated. The FAMA test was performed on sera from 229 children, and antibody titers were analyzed using fluorescence microscopy (classic FAMA) and flow cytometry (flow FAMA). For comparison, glycoprotein enzyme immunoassay (gpEIA) titer was also measured. A strong correlation was found between the flow and classic FAMA titers, and the flow FAMA and gpEIA titers, with Pearson's

Indexed as

Flow cytometryFluorescent antibody to membrane antigen testGlycoprotein enzyme immunoassayImmunogenicityVaricella-zoster virus

Identifiers

PMID39262946
PMCPMC11388681

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.