Evidence map›Paper›PMID 39261502›Full record

ArticleScientific reports2024

Pollution of the environment and building interiors during asbestos removal as a result of lack of negative pressure in the working areas.

Andrzej Obmiński

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Andrzej ObmińskiBuilding Research Institute, Filtrowa 1, 00-611, Warsaw, Poland. a.obminski@itb.pl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The paper presents examples of the consequences of the lack of negative pressure in the work zone during asbestos removal. The asbestos fibre concentrations generated in those work zones were relatively low. This was due to the leakage in barriers restricting the work zone. Therefore the asbestos content in the outside air, near the renovated rooms was increasing. In the cases discussed, these works resulted in short-term pollution of the building's outdoor air to a depth of up to 15 m. Such contamination can cover the entire interior of the building. This may lead to long-term retention of asbestos fibre in the facility, despite the completion of asbestos removal. For example, non-friable asbestos-cement sheets removal in those work conditions increased indoor air by contamination up to 3000 f/m

Indexed as

Airborne asbestos fibreAsbestosAsbestos removalBuilding materialsContaminationIndoor airOutdoor air

Identifiers

PMID39261502
PMCPMC11391016

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.