Evidence map›Paper›PMID 39260884›Full record

ArticleAJNR. American journal of neuroradiology2025

In Vitro Assessment of Vascular Injury following Stent Retriever Retraction in Clinically Relevant Endothelialized Silicone Models.

Isabelle Starr, Harrison Oen, Alyssa McCulloch, Sergey Frenklakh, Ryan Grandfield, Hana Choe, Kristen O'Halloran Cardinal

Abstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Isabelle StarrFrom the Biomedical Engineering Department (I.S., H.O., A.M., K.O.C.), Cal Poly, San Luis Obispo, California.ORCID 0009-0004-4838-8304
Harrison OenFrom the Biomedical Engineering Department (I.S., H.O., A.M., K.O.C.), Cal Poly, San Luis Obispo, California.ORCID 0009-0005-6866-4609
Alyssa McCullochFrom the Biomedical Engineering Department (I.S., H.O., A.M., K.O.C.), Cal Poly, San Luis Obispo, California.
Sergey FrenklakhStryker Neurovascular (S.F., R.G.), Fremont, California.ORCID 0009-0002-6589-4044
Ryan GrandfieldStryker Neurovascular (S.F., R.G.), Fremont, California.
Hana ChoeCommunity Neurosciences Institute (H.C.), Fresno, California.
Kristen O'Halloran CardinalFrom the Biomedical Engineering Department (I.S., H.O., A.M., K.O.C.), Cal Poly, San Luis Obispo, California kohallor@calpoly.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechanical thrombectomy devices have potential to injure the vessel during treatment of acute ischemic stroke. The goal of the current work was to tailor in vitro endothelialized silicone models for stent retriever assessment and to evaluate endothelial injury following treatment by various stent retriever designs and sizes. Clinically relevant neurovascular geometries were first modeled out of silicone, then sterilized, coated with fibronectin, placed in bioreactors, seeded with human endothelial cells, and cultivated under flow. Several sizes of 2 different commercially available stent retrievers were then deployed in, and retracted through, vessels. Vessels were immediately harvested and stained. Endothelial injury, identified as denudation, was quantified by using ImageJ. Results illustrated that endothelial injury ranged from 16%-18% in wire/microcatheter-only treated vessels, 37%-61% in 1-pass treatments, and 52%-70% in 2-pass treatments. Overall, this work showcases an in vitro approach for early stage assessment of the extent and location of vascular injury following stent retriever retraction.

Indexed as

Device RemovalEndothelium, VascularSiliconesStentsThrombectomyVascular System InjuriesEquipment DesignHumansIn Vitro TechniquesSilicones

Identifiers

PMID39260884
PMCPMC11979809

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked