Evidence map›Paper›PMID 39258711›Full record

ArticleJournal of applied clinical medical physics2024

Geometric evaluation and quantifying dosimetric impact of diverse deformable image registration algorithms on abdomen images with biomechanically modeled deformations.

Yilin Liu, Pengpeng Zhang, Jun Hong, Sadegh Alam, LiCheng Kuo, Yu-Chi Hu, Wei Lu, Laura Cerviño

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yilin LiuDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Pengpeng ZhangDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Jun HongDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Sadegh AlamDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
LiCheng KuoDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.ORCID https://orcid.org/0000-0002-0336-493X
Yu-Chi HuDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Wei LuDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Laura CerviñoDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

purposeDeformable image registration (DIR) has been increasingly used in radiation therapy (RT). The accuracy of DIR algorithms and how it impacts on the RT plan dosimetrically were examined in our study for abdominal sites using biomechanically modeled deformations.

methodsFive pancreatic cancer patients were enrolled in this study. Following the guidelines of AAPM TG-132, a patient-specific quality assurance (QA) workflow was developed to evaluate DIR for the abdomen using the TG-132 recommended virtual simulation software ImSimQA (Shrewsbury, UK). First, the planning CT was deformed to simulate respiratory motion using the embedded biomechanical model in ImSimQA. Additionally, 5 mm translational motion was added to the stomach, duodenum, and small bowel. The original planning CT and the deformed CT were then imported into Eclipse and MIM to perform DIR. The output displacement vector fields (DVFs) were compared with the ground truth from ImSimQA. Furthermore, the original treatment plan was recalculated on the ground-truth deformed CT and the deformed CT (with Eclipse and MIM DVF). The dose errors were calculated on a voxel-to-voxel basis.

resultsData analysis comparing DVF from Eclipse versus MIM show the average mean DVF magnitude errors of 2.8 ± 1.0  versus 1.1 ± 0.7 mm for stomach and duodenum, 5.2 ± 4.0  versus 2.5 ± 1.0 mm for small bowel, and 4.8 ± 4.1  versus 2.7 ± 1.1 mm for the gross tumor volume (GTV), respectively, across all patients. The mean dose error on stomach+duodenum and small bowel were 2.3 ± 0.6% for Eclipse, and 1.0 ± 0.3% for MIM. As the DIR magnitude error increases, the dose error range increase, for both Eclipse and MIM.

conclusionIn our study, an initial assessment was conducted to evaluate the accuracy of DIR and its dosimetric impact on radiotherapy. A patient-specific DIR QA workflow was developed for pancreatic cancer patients. This workflow exhibits promising potential for future implementation as a clinical workflow.

Indexed as

AlgorithmsImage Processing, Computer-AssistedOrgans at RiskPancreatic NeoplasmsRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedAbdomenBiomechanical PhenomenaHumansQuality Assurance, Health CareRadiotherapy, Image-GuidedRespirationabdomen imagingbiomechanically modeled deformationsDIRdosimetrypatient‐specific QA

Identifiers

PMID39258711
PMCPMC11633795

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.