Evidence map›Paper›PMID 39258362›Full record

Trial reportCirculation2024

Pulsed Field Ablation to Treat Paroxysmal Atrial Fibrillation: Safety and Effectiveness in the AdmIRE Pivotal Trial.

Vivek Y Reddy, Hugh Calkins, Moussa Mansour, Oussama Wazni, Luigi Di Biase, Marwan Bahu, David Newton, Christopher F Liu, William H Sauer, Sandeep Goyal and 8 more

Registry-linked trialAbstract readMulticenter StudyClinical Trial
In one paragraph

Trial report in Circulation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05293639 (Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the BWI IRE Ablation System), which is not on this map. Cited by 85 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
85citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05293639 nacompletednot on this map

Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the BWI IRE Ablation System (AdmIRE)

TypeinterventionalSponsorBiosense Webster, Inc.Ran2022 to 2023Enrolled362ConditionsAtrial FibrillationArmsPulse Field Ablation
3 · Its place in the literature

Who cites it

85 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Guideline
  2. Trial
  3. Pulmonary vein isolation durability in a randomized trial comparing fluoroscopy-only vs. electroanatomic mapping strategies for pulmonary vein isolation with balloon-in-basket pulsed-field ablation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Trial
  4. Trial
  5. Trial
  6. Impact of saline irrigation on haemolysis, silent cerebral lesion incidence, thermal dynamics, and bubble formation in pulsed field ablation with a variable-loop circular catheter.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Trial
  7. Wide-Antral pulmonary vein isolation in patients undergoing atrial fibrillation ablation with a Single-Shot technique: rationale and design of the WIDER-PVI trial.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Trial
  8. Procedural characteristics and clinical outcomes from same-day discharge after pulsed field ablation treatment for atrial fibrillation: an admIRE trial sub-analysis.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Trial
  9. Safety and effectiveness of the first balloon-in-basket pulsed field ablation system for the treatment of atrial fibrillation: VOLT CE Mark Study 6-month results.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Trial
  10. First-in-human trial of atrial fibrillation ablation using real-time tissue optical assessment to predict pulsed field lesion durability.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Trial
  11. Article
  12. Review
  13. Artificial intelligence-intracardiac echocardiography-guided pulsed field ablation of atrial fibrillation with variable-loop circular catheter.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Article
  14. Article
  15. Article
  16. Article
  17. Post-market individual-report phenotypes after pulsed-field ablation for atrial fibrillation in a food and drug administration database.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2026
    Article
  18. Article
  19. Article
  20. Review

25 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Vivek Y ReddyHelmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, New York, NY (V.Y.R.).
Hugh CalkinsJohns Hopkins Medical Institutions, Baltimore, MD (H.C.).ORCID 0000-0002-9262-9433
Moussa MansourMassachusetts General Hospital, Boston (M.M.).
Oussama WazniCleveland Clinic Foundation, OH (O.W., A.H.).ORCID 0000-0001-7115-7716
Luigi Di BiaseMontefiore Health System at Albert Einstein College of Medicine, New York, NY (L.D.B.).ORCID 0000-0001-6508-4047
Marwan BahuPhoenix Cardiovascular Research Group, AZ (M.B.).
David NewtonMemorial Health University Medical Center, Savannah, GA (D. Newton).
Christopher F LiuNew York Presbyterian-Weill Cornell Medicine, NY (C.F.L.).ORCID 0000-0001-8852-4551
William H SauerBrigham & Women's Hospital, Boston, MA (W.H.S.).ORCID 0009-0006-8556-3612
Sandeep GoyalPiedmont Heart Institute, Atlanta, GA (S.G.).ORCID 0000-0001-6915-9835
Vivek IyerMarin Health Medical Center, Larkspur, CA (V.I.).
Devi NairSt. Bernard's Medical Center & Arrhythmia Research Group, Jonesboro, AR (D. Nair).ORCID 0000-0001-8253-947X
Charles AthillSan Diego Cardiac Center, CA (C.A.).ORCID 0009-0001-9423-2261
Ayman HusseinCleveland Clinic Foundation, OH (O.W., A.H.).ORCID 0000-0002-8359-1525
Patrick WhalenWake Forest Baptist Health, Winston-Salem, NC (P.W.).
Daniel MelbyMinneapolis Heart Institute, MN (D.M.).
Andrea NataleTexas Cardiac Arrhythmia Research Foundation, Austin (A.N.).ORCID 0000-0002-5487-0728
AdmIRE Trial Investigators

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEvidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining efficacy. However, the lack of a fully integrated mapping system, a staple technology of most modern electrophysiology procedures, poses limitations in lesion creation and workflow options. A novel variable-loop PFA catheter integrated with an electroanatomic mapping system has been developed that allows for real-time nonfluoroscopic procedural guidance and lesion indexing as well as feedback of tissue-to-catheter proximity. AdmIRE (Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the Bosense-Webster Irreversible Electroporation Ablation System), a multicenter, single-arm, Food and Drug Administration investigational device exemption study, evaluated the long-term safety and effectiveness of this integrated PFA system in a large United States-based drug-refractory symptomatic paroxysmal atrial fibrillation patient population.

methodsUsing the PFA catheter with a compatible electroanatomic mapping system, patients with drug-refractory symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation. The primary safety end point was primary adverse event within 7 days of ablation. The primary effectiveness end point was a composite end point that included 12-month freedom from documented atrial tachyarrhythmia (ie, atrial fibrillation, atrial tachycardia, atrial flutter) episodes, failure to achieve pulmonary vein isolation, use of a nonstudy catheter for pulmonary vein isolation, repeat procedure (except for one redo during blanking), taking a new or previously failed class I or III antiarrhythmic drug at higher dose after blanking, or direct current cardioversion after blanking.

resultsAt 30 centers, 277 patients with paroxysmal atrial fibrillation (61.5±10.3 years of age; 64.3% male) in the pivotal cohort underwent PFA. More than 25% of the procedures were performed without fluoroscopy. Median (Q1, Q3) pulmonary vein isolation procedure, fluoroscopy, and transpired PFA application times were 81.0 (61.0, 112.0), 7.1 (0.00, 14.3), and 31.0 (24.8, 40.9) minutes, respectively. The primary adverse event rate was 2.9% (8 of 272), with the most common complication being pericardial tamponade. The 12-month primary effectiveness end point was 74.6%. The 1-year freedom from atrial fibrillation, atrial tachycardia, or atrial flutter recurrence rate after blanking was 75.4%. Substantial improvements in quality of life were observed as early as 3 months after the procedure, concurrent with a reduction in multiple health care use measures.

conclusionsAdmIRE confirmed the safety and effectiveness of the variable-loop PFA catheter, with short procedure and PFA application times and low fluoroscopy exposure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05293639.

Indexed as

Atrial FibrillationCatheter AblationAgedFemaleHumansMaleMiddle AgedPulmonary VeinsTreatment Outcomeatrial fibrillationcatheterspulmonary veins

Identifiers

PMID39258362
PMCPMC11458102

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.