Evidence map›Paper›PMID 39258343›Full record

ArticleAdvanced materials (Deerfield Beach, Fla.)2024

The Effect of Relative Humidity in Conductive Atomic Force Microscopy.

Yue Yuan, Mario Lanza

Abstract read
In one paragraph

Article in Advanced materials (Deerfield Beach, Fla.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Environmental Control of Ferroelectricity in Hafnia Films.Advanced materials (Deerfield Beach, Fla.) · 2025
    Article
  4. Article
  5. A Multimodal Humidity Adaptive Optical Neuron Based on a MoWSAdvanced materials (Deerfield Beach, Fla.) · 2025
    Article
  6. The Effect of Relative Humidity in Conductive Atomic Force Microscopy.Advanced materials (Deerfield Beach, Fla.) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yue YuanMaterials Science and Engineering Program, Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia.ORCID https://orcid.org/0000-0002-7249-0411
Mario LanzaMaterials Science and Engineering Program, Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia.ORCID https://orcid.org/0000-0003-4756-8632

Funding

King Abdullah University of Science and Technology
6 · The paper itself

Abstract

Conductive atomic force microscopy (CAFM) analyzes electronic phenomena in materials and devices with nanoscale lateral resolution, and it is widely used by companies, research institutions, and universities. Most data published in the field of CAFM is collected in air at a relative humidity (RH) of 30-60%. However, the effect of RH in CAFM remains unclear because previous studies often made contradictory claims, plus the number of samples and locations tested is scarce. Moreover, previous studies on this topic did not apply current limitations, which can degrade the CAFM tips and generate false data. This article systematically analyzes the effect of RH in CAFM by applying ramped voltage stresses at over 17,000 locations on ten different samples (insulating, semiconducting, and conducting) under seven different RH. An ultra-reliable setup with a 110-pA current limitation during electrical stresses is employed, and excellent CAFM tip integrity after thousands of tests is demonstrated. It is found that higher RH results in increased currents due to the presence of a conductive water meniscus at the tip/sample junction, which increases the effective area for electron flow. This trend is observed in insulators and ultra-thin semiconductors; however, in thicker semiconductors the electron mean free path is high enough to mask this effect. Metallic samples show no dependence on RH. This study clarifies the effect of relative humidity in CAFM, enhances understanding of the technique, and teaches researchers how to improve the reliability of their studies in this field.

Indexed as

2D materialsconductive atomic force microscopymetrologynanoelectronicsrelative humidity

Identifiers

PMID39258343
PMCPMC11656041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.