Sacroiliac joint fusion guided by intraoperatively superimposed virtual surgical planning using simulated fluoroscopic images.

Steven Lankheet, Nick Kampkuiper, Jorm Nellensteijn, Edsko Hekman, Gabriëlle Tuijthof, Femke Schröder, Maaike Koenrades

Abstract read
In one paragraph

Article in Brain & spine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Steven LankheetMedical 3D Lab, Medical Spectrum Twente, Enschede, the Netherlands.
Nick KampkuiperMedical 3D Lab, Medical Spectrum Twente, Enschede, the Netherlands.
Jorm NellensteijnDepartment of Orthopedic Surgery, Medical Spectrum Twente, Enschede, the Netherlands.
Edsko HekmanDepartment of Biomechanical Engineering, Faculty of Engineering Technology, Technical Medical Center, University of Twente, Enschede, the Netherlands.
Gabriëlle TuijthofDepartment of Biomechanical Engineering, Faculty of Engineering Technology, Technical Medical Center, University of Twente, Enschede, the Netherlands.
Femke SchröderMedical 3D Lab, Medical Spectrum Twente, Enschede, the Netherlands.
Maaike KoenradesMedical 3D Lab, Medical Spectrum Twente, Enschede, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Sacroiliac joint fusion (SIJF) is a minimally invasive treatment for sacroiliac (SI) dysfunction. It involves placing implants through the SI joint under fluoroscopic guidance, requiring precise implant positioning to avoid nerve injury. Preoperative virtual surgical planning (VSP) aids in optimal positioning, but replicating it accurately in the operating room is challenging. Research question: This study aims to assess the feasibility of superimposing VSP onto intraoperative fluoroscopic images to aid in optimal implant placement. Material and methods: A method for intraoperative guidance using 3D/2D registration was developed and tested during SIJF as an available and potentially efficient alternative for costly and more invasive navigation systems. Preoperatively, a VSP is performed and simulated fluoroscopic images are generated from a preoperative CT scan. During surgery, the simulated image that visually best matches the intraoperative fluoroscopic image is selected. Subsequently, the VSP is superimposed onto the intraoperative fluoroscopic image using a developed script-based workflow. The surgeon then places the implants accordingly. Postoperative implant placement accuracy was evaluated. Results: Five interventions were performed on five patients, resulting in a total of 15 placed implants. Minor complications without clinical consequences occurred in one case, primarily attributable to the patient's anatomy and pathological manifestations. Mean deviations at implant apex and 3D angle were 4.7 ± 1.6 mm and 3.5 ± 1.3°, respectively. Discussion and conclusions: The developed intraoperative workflow was feasible and resulted in implants placed with low deviations from the VSP. Further research is needed to automate and validate this method in a larger cohort.

Indexed as

Computer-assisted surgeryMinimally invasive sacroiliac joint fusionSimulated fluoroscopic imagesVirtual surgical planning

Identifiers

PMID39257723
PMCPMC11386036

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.