Evidence map›Paper›PMID 39257571›Full record

ArticlePhysics and imaging in radiation oncology2024

Individualized 3D-printed applicators for magnetic resonance imaging-guided brachytherapy in nasal vestibule cancer.

Mischa de Ridder, Milena Smolic, Maarten Kastelijns, Samantha Kloosterman, Stefan van der Vegt, Johannes A Rijken, Ina M Jürgenliemk-Schulz, Homan Dehnad, Petra S Kroon, Marinus A Moerland

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Breakthroughs in modern brachytherapy are transforming cancer care.Physics and imaging in radiation oncology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mischa de RidderDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Milena SmolicDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Maarten KastelijnsDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Samantha KloostermanDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Stefan van der VegtDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Johannes A RijkenDepartment of Head and Neck Surgical Oncology, UMC Utrecht, Utrecht, the Netherlands.
Ina M Jürgenliemk-SchulzDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Homan DehnadDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Petra S KroonDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.
Marinus A MoerlandDepartment of Radiation Oncology, UMC Utrecht, Utrecht, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Brachytherapy is treatment of choice for early stage nasal vestibule cancer. Over the years improvements were achieved by means of image guided target definition, interstitial implant techniques and also individual mold techniques. The aim of this study was to improve the technique of the implant so that the need for interstitial catheters can be limited by making use of patient individualized 3D-printed applicators. Materials and Methods: In 19 patients 3D-printed applicators were used to deliver pulse dose rate (PDR) brachytherapy. All patients underwent computed tomography (CT) and magnetic resonance imaging (MRI). A pre-plan with tumor delineation and manually optimized catheter positions to achieve tumor coverage was made. Based on the pre-plan a 3D-printed applicator was manufactured. Dose was evaluated by several indices: Conformity Index, Healthy Tissues Conformity Index, Dose Homogeneity Index, Dose non-uniformity ratio, Conformal index and high dose (HD) index. Results: A high target coverage was achieved, with a median V100% Conclusions: This study shows that using 3D-printed applicators limits the need for interstitial catheters and also limits the high doses in normal tissue.

Indexed as

Brachytherapyhead and neck cancer 3D-printNasal vestibule cancer

Identifiers

PMID39257571
PMCPMC11386294

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.