ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2025
Series Multiblood Pump Design With Dual Activation for Pediatric Patients With Heart Failure.
Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparison of a Miniaturized Implantable Two-Stage Rotodynamic Blood Pump to Equivalent Single-Stage Concepts.Artificial organs · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The translational development of pediatric ventricular assist devices (VADs) lags years behind adult device options, negatively impacting pediatric patient outcomes. To address this need, we are developing a novel, series-flow, double-blood pump VAD that integrates an axial and centrifugal pump into a single device. The axial pump is used for initial circulatory assistance in younger patients; then, an internal activation mechanism triggers the centrifugal pump to activate in line with the axial pump, providing additional pressure and flow to match pediatric patient growth cycles. Here, we focused on the design and improvement of the device flow paths through computational analysis and in vitro hydraulic testing of a prototype. We estimated pressure-flow generation, fluid scalar stresses, and blood damage levels. In vitro hydraulic tests correlated well with shear stress transport (SST) predictions, with an average deviation of 4.5% for the complex, combined flow path. All data followed expected pump performance trends. The device exceeded target levels for blood damage in the blade tip clearances, and this must be both investigated and addressed in the next design phase. These study findings establish a strong foundation for the future development of the Drexel Double-Dragon VAD .
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.