ArticlePloS one2024
Two-dimensional Graphene/MoS2 vertical heterostructure for detection of hemoglobin concentration in blood samples.
Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study demonstrates the use of computational methods to simulate the molecular dynamics involved in hemoglobin concentration sensing, utilizing Material Studio and the TCAD Silvaco device simulator. A non-invasive and flexible Graphene/MoS2 heterostructure has been proposed for sensing hemoglobin concentration in blood samples. The findings reveal a notable shift in the wavelength-dependent refractive index and extinction coefficient, as well as significant changes in the absorption coefficient and reflectivity of the Graphene/MoS2 heterostructure in response to different hemoglobin concentrations, specifically within an approximate range of 0.3 μm to 1 μm. Moreover, the spectral response of the heterostructure demonstrates that at a particular wavelength of approximately 600 nm, a maximum response is obtained. This wavelength can be considered optimal for detecting various levels of hemoglobin using this heterostructure. The anticipated outcome is a comprehensive understanding of the fundamental principles, ultimately resulting in the development of an exceptionally sensitive platform for detecting hemoglobin concentration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.