1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Matthew C KaneSurgery, East Tennessee State University Quillen College of Medicine, Johnson City, USA.
Harold E CatesOrthopedic Surgery, Tennessee Orthopedic Foundation for Education and Research, Knoxville, USA.
Iou-Ren ChangOrthopedic Surgery, OhioHealth Doctors Hospital, Columbus, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The importance of proper prosthetic placement has been confirmed in numerous studies. The objective of this study was to compare the planned resection angles to the verified intraoperative angles of femoral and tibial varus/valgus, tibial slope, and femoral flexion for each total knee performed using intramedullary (IM) cut guides for both distal femur and proximal tibia cuts. A total of 1,000 total knee arthroplasties (TKAs) were evaluated for this study. Intraoperative cut-check technology was used to show real-time validation of these resection angles. Assuming an acceptable range of within 2° of the planned cuts, results show the femoral varus/valgus angles were 75% accurate, the femoral flexion angles were 50.8% accurate, the tibial cuts were 95.2% accurate in the coronal plane, and the tibial slope was the least accurate with only 50.3% within the acceptable range. This showed that IM guides are reasonably accurate in producing desired angles in the coronal plane but less accurate in the sagittal plane, with a greater number of outliers in femoral flexion and posterior slope. Surgeons need to be aware of potential cutting errors when using IM guides as they affect the overall alignment of the implant, and real-time verification technology is available to verify the accuracy of the cuts.

Indexed as

angle accuracyintramedullary guiderobotic total knee arthroplastytotal knee arthroplasty techniquetotal knee arthroplasty (tka)

Identifiers

PMID39246632
PMCPMC11380561

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.