Evidence map›Paper›PMID 39245332›Full record

ArticleThe American journal of cardiology2024

Supra-Annular Self-Expanding Versus Balloon-Expandable Valves for Valve-in-Valve Transcatheter Aortic Valve Replacement.

Danial Ahmad, Michel Pompeu Sá, Sarah Yousef, James A Brown, Nandini Doshi, Dustin E Kliner, Derek Serna-Gallegos, Yisi Wang, Floyd Thoma, Catalin Toma and 4 more

Abstract readComparative Study
In one paragraph

Article in The American journal of cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Escalating Diameter Buddy Balloon in Transcatheter Aortic Valve Implantation With Complex Aortic Arch.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  4. Balloon-Expandable Versus Self-Expanding Valves in Low-Flow, Low-Gradient Aortic Stenosis: Does Valve Type Matter?Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  5. Article
  6. Intra-Annular Versus Supra-Annular Self-Expanding Valves for Valve-in-Valve TAVR.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Danial AhmadDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Michel Pompeu SáDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Sarah YousefDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
James A BrownDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Nandini DoshiDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.
Dustin E KlinerHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Derek Serna-GallegosDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Yisi WangHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Floyd ThomaHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Catalin TomaHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Amber MakaniHeart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Irsa HasanDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Dave WestDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Ibrahim SultanDivision of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania. Electronic address: sultani@upmc.edu.

Funding

Cardiothoracic Surgery Research Training ProgramT32HL160526 · NHLBI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI JAMES D LUKETICH, Julie A Phillippi · 2022 to 2026
$1.5M
NHLBI NIH HHS T32 HL160526
6 · The paper itself

Abstract

Self-expanding (SE) and balloon-expandable (BE) transcatheter heart valves (THVs) have not been extensively studied in valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). We compared outcomes of supra-annular SE and BE THVs used for ViV-TAVR through a retrospective analysis of institutional data (2013 to 2023) including all patients who underwent ViV-TAVR (TAVR in previous surgical aortic valve replacement). Unmatched and propensity-matched (1:1) comparisons of clinical and echocardiographic outcomes were undertaken in SE and BE THVs along with Kaplan-Meier survival analysis. A total of 315 patients who underwent ViV-TAVR were included, of whom 73% received an SE THV. Median age was 77 years, and women comprised 42.5% of the population. Propensity-score matching (1:1) yielded 81 matched pairs. Implanted aortic valve size was comparable in the groups (23 mm [23 to 26] vs 23 mm [23 to 26], p = 0.457). At 30 days after ViV-TAVR, the SE group had a lower mean aortic valve gradient (14 mm Hg [11 to 18] vs 17.5 mm Hg [13 to 25], p = 0.007). A greater number of patients with BE THV had severe prosthesis-patient mismatch (16% vs 6.2%, p = 0.04). At 1-year follow-up, the SE THV group had a lower aortic valve gradient (14.0 mm Hg [9.6 to 19] vs 17 mm Hg [13 to 25], p = 0.04) than that of the BE THV group; 30-day mortality was 2.7%, whereas 1-year mortality was 7.5% and comparable in the groups. Survival and stroke incidence were similar in the groups up to 5 years. In conclusion, SE and BE THVs had comparable survival after ViV-TAVR. The higher residual aortic valve gradients in BE THVs are likely due to valve design and warrant long-term evaluation for potential structural valve degeneration.

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisProsthesis DesignTranscatheter Aortic Valve ReplacementAgedAged, 80 and overAortic ValveEchocardiographyFemaleHumansMalePropensity ScoreRetrospective StudiesTreatment OutcomeTAV-in-SAVTAVRTAVR after SAVRvalve-in-valveViV-TAVR

Identifiers

PMID39245332
PMCPMC12317673

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.