ArticleClinical orthopaedics and related research2025
Taper Junction Subsidence Occurs in Modular Tumor Endoprostheses: How Concerned Should We Be?
Article in Clinical orthopaedics and related research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- CORR Insights®: Taper Junction Subsidence Occurs in Modular Tumor Endoprostheses: How Concerned Should We Be?Clinical orthopaedics and related research · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAdvancements in musculoskeletal oncologic treatment have allowed for longer survival of patients with malignant bone tumors and the associated longer use of tumor endoprostheses in those who have had such reconstructions. Several studies have reported on increased serum metal ions with the use of such implants. Modularity in these implants introduces the risk of taper junction corrosion and subsidence resulting in metal wear particle release that may cause an adverse local tissue reaction or systemic toxicity. Additionally, these implants contain a large surface area of cobalt and chromium. It is unclear whether the source of the increased serum ion levels was due to the taper junction corrosion or the implant itself. To our knowledge, no prior study has reported on taper junction subsidence. QUESTIONS/PURPOSES: In this study we sought (1) to determine survivorship free from radiographic taper junction subsidence in a femoral modular tumor endoprosthesis, and (2) to identify the implant characteristics in the endoprostheses associated with taper subsidence.
methodsBetween January 1996 and February 2020, the senior author performed 150 proximal or distal femur replacements following resections of soft tissue or bone tumors of the thigh and femur. Of those, 6% (9 of 150) of patients were lost to follow-up before 2 years, 25% (37 of 150) could not be analyzed due to absence of plain radiographs during follow-up, and 13% (20 of 150) died before 2 years follow-up, leaving 56% (84 of 150) for analysis in this retrospective study, with a median time for analysis of 14 years (range 2 to 31 years) after the index resection and endoprosthetic reconstruction for patients with distal femur replacements and 5 years (range 2 to 19 years) for patients with proximal femur replacement. Radiographs involving the entire implant were evaluated for the presence or absence of subsidence of the taper junction that was evident and clear to see if present. The association between the number of taper junctions, the length of resection, the number of collapsed junctions, and the time to collapse from the initial surgery were examined using regression analysis.
resultsOverall, 14% (12 of 84) patients with a distal femur replacement had radiographic collapse of at least one of the modular tapers. Survivorship free from taper subsidence was 91% (95% CI 86% to 96%) at 10 years and 84% (95% CI 78% to 90%) at 20 years. All patients were in the distal femur replacement group. The median follow-up of patients with subsidence was 15 years (range 5 to 26). Fifty-eight percent (7 of 12) of patients had two junctions involved, 25% (3 of 12) had three junctions, and 17% (2 of 12) had one junction involved. All but one patient had subsidence in a single junction. The median time to subsidence was 15 years (range 4.5 to 24.0 years). The subsidence was progressive in all patients who demonstrated it. The taper junction subsidence was complete in 75% (9 of 12) of patients and partial in 25% (3 of 12). Univariate and multivariable regression analyses did not show that the risk factors we studied were associated with subsidence. Two patients with junction subsidence were revised, one for taper fracture and one during busing exchange for distal junction subsidence.
conclusionTaper damage with late and progressive subsidence of the intervening junction is not uncommon after distal femur replacement. The impact of such a complication is still unknown. Further studies should examine the long-term outcomes and correlate them with metal ion levels. LEVEL OF EVIDENCE: Level III, therapeutic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.