ArticleJournal of applied clinical medical physics2024

Assessment of scintillation and Cherenkov imaging as beam shape verification method in CyberKnife® radiotherapy.

Fengwei Cui, Tao Jin, Mingzhu Li, Lei Zhu, Xing Di, Huaguang Zhu

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fengwei CuiCyberKnife Center, Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China.
Tao JinCyberKnife Center, Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China.
Mingzhu LiDepartment of Oncology, The First Hospital of Hebei Medical University, Hebei Medical University, Shijiazhuang, China.
Lei ZhuDepartment of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan City, Shandong Province, China.
Xing DiCyberKnife Center, Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China.
Huaguang ZhuCyberKnife Center, Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe goal of this study is to assess the utility of Cherenkov imaging (CI) and scintillation imaging (SI) as high-resolution techniques to measure CyberKnife® beam shape quantitatively at the irradiation surface in quality assurance (QA).

methodsThe EMCCD camera captured scintillation and Cherenkov photons arising from 6 MV x-ray dose deposition produced by the CyberKnife® VSI System. Two imaging methods were done at source to surface distance of 800 cm with the same field size, ranging from 10 to 60 mm using fixed cones and iris collimators. The output sensitivity and constancy were measured using the SI and CI, and benchmarked against an ionization chamber. Line profiles of each beam measured by optical imaging were compared with film measurement. Position shifts were introduced to test the sensitivity of SI and CI to small beam position deviations. To assess reproducibility, the beam measurements were tested three times on 5 consecutive days.

resultsBoth systems exhibited comparable sensitivity to the ionization chamber in response to fluctuations in CyberKnife® output. The beam profiles in SI matched well with the measured film image, with accuracy in the range of ± 0.20 and ± 0.26 mm standard deviation for the circle and iris field, respectively. The corresponding accuracy measured by CI is in the range of ± 0.25 and ± 0.33 mm, respectively. These are all within the tolerance recommended by the guidelines of CyberKnife® QA. The accuracy measured by SI and CI for 1 mm beam position shift within 0.21 and 0.45 mm tolerance, respectively. Repeatability measurements of the beam have shown a standard deviation within 0.94 mm.

conclusionsSI and CI techniques are tested to provide a valid way to measure CyberKnife® beam shape in this study. Meanwhile, the systematic comparison of SI and CI also provides evidence for the measurement methods selection appropriately.

Indexed as

Phantoms, ImagingRadiosurgeryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedScintillation CountingHumansImage Processing, Computer-AssistedNeoplasmsParticle AcceleratorsPhotonsQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedCherenkov imagingCyberKnife® radiotherapyQAscintillation imaging

Identifiers

PMID39243112
PMCPMC11633798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.