Evidence map›Paper›PMID 39242670›Full record

ArticleScientific reports2024

Biomechanical evaluation of an experimental internal ring fixator (RingFix) for stabilization of pelvic ring injuries on an osteoporotic bone model.

Charlotte Arand, Christian Hartung, Dorothea Mehler, Erol Gercek, Jochen Wollstädter, Daniel Wagner, Pol M Rommens

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Iliosacral screw osteosynthesis - state of the art.Archives of orthopaedic and trauma surgery · 2025
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Charlotte ArandDepartment of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany. charlotte.arand@unimedizin-mainz.de.ORCID 0000-0003-3840-0299
Christian HartungDepartment of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Dorothea MehlerDepartment of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.ORCID 0000-0003-2876-7687
Erol GercekDepartment of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.ORCID 0000-0002-5996-2947
Jochen WollstädterDepartment of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.
Daniel WagnerDepartement of Orthopedics and Tramatology, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland.ORCID 0000-0003-4455-1018
Pol M RommensDepartment of Orthopaedics and Traumatology, University Medical Center, Langenbeckstraße 1, 55131, Mainz, Germany.ORCID 0000-0002-5175-3876

Funding

Mainzer Trauma-Stiftung 2018-01
6 · The paper itself

Abstract

During the last decades, effective pain reduction and early mobilization were identified as the central priorities in therapy of insufficiency fractures of the pelvis. For operative treatment minimally-invasive stabilization techniques are favored. While there is consensus on the significance of sufficient dorsal stabilization the role of additional fixation of the anterior fracture component stays under discussion. Within the present study we developed an internal ring fixator system (RingFix) with the question whether an in-itself-closed construct can improve stability of the entire ring structure. RingFix was evaluated on an osteoporotic bone model with a standardized FFP IIIc fracture within an established biomechanical setup regarding its primary stabilization potential. Further, it was compared to transiliac-transsacral screw fixation with and without stabilization of the anterior fracture component. The transiliac-transsacral fixation with separate screw fixation of the anterior fracture showed significantly higher stability than the RingFix and the transiliac-transsacral screw fixation without anterior stabilization. Our results show that stabilization of the anterior fracture component relevantly improves the stability of the entire ring construct. As a bridging stabilizer, RingFix shows biomechanical advantages over an isolated dorsal fracture fixation, but inferior results than direct stabilization of the single fracture components.

Indexed as

Fracture Fixation, InternalPelvic BonesBiomechanical PhenomenaBone ScrewsFractures, BoneHumansInternal FixatorsOsteoporosisInsufficiency fractureMinimally-invasive fracture fixationPelvic ring fractureRing fixator

Identifiers

PMID39242670
PMCPMC11379716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.