Evidence map›Paper›PMID 39242657›Full record

ArticleScientific reports2024

Sub-attosecond-precision optical-waveform stability measurements using electro-optic sampling.

Syed A Hussain, Christina Hofer, Maximilian Högner, Wolfgang Schweinberger, Theresa Buberl, Daniel Bausch, Marinus Huber, Ferenc Krausz, Ioachim Pupeza

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Syed A Hussain *Max Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Christina Hofer *Max Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Maximilian HögnerMax Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Wolfgang SchweinbergerLudwig Maximilians University of Munich, Am Coulombwall 1, 85748, Garching, Germany.
Theresa BuberlMax Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Daniel BauschMax Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Marinus HuberMax Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Ferenc KrauszMax Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany.
Ioachim PupezaMax Planck Institute of Quantum Optics, Hans-Kopfermann-Str. 1, 85748, Garching, Germany. ioachim.pupeza@rptu.de.

Funding

Deutsche Forschungsgemeinschaft 390713860European Research Council 101088303Research project "SARSCoV2Dx", German Federal Ministry of Education and Research, within the funding program Photonics Research Germany 13N15742
6 · The paper itself

Abstract

The generation of laser pulses with controlled optical waveforms, and their measurement, lie at the heart of both time-domain and frequency-domain precision metrology. Here, we obtain mid-infrared waves via intra-pulse difference-frequency generation (IPDFG) driven by 16-femtosecond near-infrared pulses, and characterise the jitter of sub-cycle fractions of these waves relative to the gate pulses using electro-optic sampling (EOS). We demonstrate sub-attosecond temporal jitter at individual zero-crossings and sub-0.1%-level relative amplitude fluctuations in the 10-kHz-0.625-MHz band. Chirping the nearly-octave-spanning mid-infrared pulses uncovers wavelength-dependent attosecond-scale waveform jitter. Our study validates EOS as a broadband (both in the radio-frequency and the optical domains), highly sensitive measurement technique for the jitter dynamics of optical waveforms. This sensitivity reveals outstanding stability of the waveforms obtained via IPDFG and EOS, directly benefiting precision measurements including linear and nonlinear (infrared) field-resolved spectroscopy. Furthermore, these results form the basis toward EOS-based active waveform stabilisation and sub-attosecond multi-oscillator synchronisation/delay tracking.

Identifiers

PMID39242657
PMCPMC11379936

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.