Evidence map›Paper›PMID 39242515›Full record

ArticleBMC anesthesiology2024

Ultrasonic assessment of gastric solid contents in patients undergoing upper endoscope with sedation.

Jing Wang, Xuan Yu, Ying Wang, JieLei Xu, Zhao Wang, Yi Zhang

Abstract read
In one paragraph

Article in BMC anesthesiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jing WangDepartment of Anesthesiology, the Second Affiliated Hospital of Zunyi Medical University, Intersection of Xinglong Avenue and Xinpu Avenue, Zunyi, 563000, Zunyi, China.
Xuan YuDepartment of Anesthesiology, the Second Affiliated Hospital of Zunyi Medical University, Intersection of Xinglong Avenue and Xinpu Avenue, Zunyi, 563000, Zunyi, China.
Ying WangDepartment of the Second Clinical College, the Second Affiliated Hospital of Zunyi Medical University, Zunyi, China.
JieLei XuDepartment of Anesthesiology, the Second Affiliated Hospital of Zunyi Medical University, Intersection of Xinglong Avenue and Xinpu Avenue, Zunyi, 563000, Zunyi, China.
Zhao WangDepartment of Anesthesiology, the Second Affiliated Hospital of Zunyi Medical University, Intersection of Xinglong Avenue and Xinpu Avenue, Zunyi, 563000, Zunyi, China.
Yi ZhangDepartment of Anesthesiology, the Second Affiliated Hospital of Zunyi Medical University, Intersection of Xinglong Avenue and Xinpu Avenue, Zunyi, 563000, Zunyi, China. zyzy@zmu.edu.cn.

Funding

the Guizhou Provincial Health Commission gzwkj2022-127the Second Affiliated Hospital of Zunyi Medical University (SQ-2021-11)
6 · The paper itself

Abstract

backgroundPerioperative reflux aspiration presents a grave concern during sedation or general anesthesia, particularly when solid gastric contents prompt acute upper respiratory obstruction, potentially resulting in fatal consequences for patients. Currently, there are limited means for promptly assessing solid gastric contents in clinical settings. Therefore, this study examined the efficacy of ultrasound assessment for solid gastric contents, offering a rapid and non-invasive approach for early detection and decision-making regarding interventions.

methodsThe study included 400 patients scheduled for upper endoscopy procedures, which encompassed both gastroscope and gastroscope combined colonoscopy examinations with sedation. Ultrasound scanning of the antrum was performed while patients were positioned semi-sitting or in the right lateral decubitus (RLD) posture. The evaluation of solid gastric contents relied on direct visual observation during endoscopy. Gastric volume measurement occurred subsequent to endoscopic suction of gastric contents. Receiver operating characteristic curves were utilized to assess the effectiveness of ultrasonography in discerning solid contents.

resultSeven patients undergoing gastroscope with sedation were found to have solid gastric contents. The sensitivity, specificity, positive predictive value, and negative predictive value of the ultrasound qualitative evaluation of solid contents were 85.7%, 99%, 60%, and 99.7%, respectively.

conclusionSolid stomach contents can be evaluated qualitatively with reasonable accuracy using ultrasonography. Additionally, in patients undergoing upper endoscopy and assessed to have solid gastric contents with ultrasound, administration of mild sedation is recommended.

trial registrationwww.chictr.org.cn (ChiCTR2100048994); registered 19/07/2021.

Indexed as

Gastrointestinal ContentsUltrasonographyAdultAgedColonoscopyFemaleGastroscopesHumansMaleMiddle AgedProcedural SedationProspective StudiesSensitivity and SpecificityGastric solid contentsGastric ultrasoundUpper endoscope

Identifiers

PMID39242515
PMCPMC11378558

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.