ArticleIndian pacing and electrophysiology journal
Retrievable dual-chamber leadless pacemaker implant (Aveir DR) in an adult patient with congenital heart disease.
Article in Indian pacing and electrophysiology journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Dual Chamber Aveir Retrievable Leadless Pacemaker Implant in a Patient with a Senning Baffle and Subcutaneous ICD.Pediatric cardiology · 2026Article
- Innovative Management of Rhythm Disorders in Adults with Congenital Heart Disease.Methodist DeBakey cardiovascular journal · 2026Review
- Recommendations on the use of a leadless dual-chamber pacemaker.Cardiology journal · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Leadless pacemakers have demonstrated potential as a transvenous pacing option in Adult Congenital Heart Disease patients. Aveir™ single-chamber (VR) leadless pacemakers have demonstrated safety in patients without congenital heart disease in a dual chamber approach. We present a case of dual-chamber pacing using the Aveir dual-chamber (DR) leadless pacemaker in a patient with repaired dextro-transposition of the great arteries with ventricular septal defect (VSD) surgical closure. A 26-year-old male patient with a history of transposition of the great arteries status post arterial switch and VSD repair neonatally had complicated second degree atrioventricular block and sinus node dysfunction necessitating pacemaker placement. Epicardial single-chamber ventricular pacemaker was placed neonatally, which was switched to dual-chamber pacemaker at age 17 due to malfunction. Recent fracture of pacemaker leads led to implantation of new dual chamber leadless pacemaker. Removal of previous pacemaker leads via mechanical extraction occurred and implantation of Aveir DR leadless pacemaker was performed under anesthesia via right femoral vein access without complication. Follow-up demonstrated Aveir VR threshold of 1.0V@0.2 ms, R-wave of 8.9mV, impedance of 490Ω, and the Aveir AR threshold of 0.75V@0.2 ms, P-wave of 3.7mV, and impedance of 400Ω. This case demonstrates safety and efficacy of dual chamber leadless pacemaker implantation in an ACHD patient.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.