ArticleClinical and experimental emergency medicine2025

A rapid noninvasive wearable device for assessing cardiac troponin I level.

William Franklin Peacock, Karina Melissa Soto-Ruiz, Allan S Jaffe, Brian R Tiffany, Simon A Mahler, Brian W Patterson, Alan H B Wu, Robert Christenson

Abstract read
In one paragraph

Article in Clinical and experimental emergency medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

William Franklin PeacockDepartment of Emergency Medicine, Baylor College of Medicine, Houston, TX, USA.
Karina Melissa Soto-RuizComprehensive Research Associates LLC, Houston, TX, USA.
Allan S JaffeDepartment of Cardiology, Mayo Clinic, Rochester, MN, USA.
Brian R TiffanyDepartment of Emergency Medicine, Chandler Regional Medical Center, Chandler, AZ, USA.
Simon A MahlerDepartment of Emergency Medicine, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
Brian W PattersonBerbee Walsh Department of Emergency Medicine, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
Alan H B WuDepartment of Laboratory Medicine, University of California, San Francisco, CA, USA.
Robert ChristensonDepartment of Laboratory Medicine, University of Maryland, Baltimore, MD, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveChest pain, a common emergency department presentation, requires rapid evaluation. The current gold standard of care is serial troponin measurements from blood draws along with an electrocardiogram and clinical presentation. However, an optical technology-based noninvasive wearable device, the Infrasensor, which can rapidly and transcutaneously assesses cardiac troponin I (cTnI), was recently developed. We aimed to perform a pilot study to evaluate the performance of the Infrasensor in cTnI defined cohorts.

methodsThis was a 10-hospital prospective observational study in healthy US subjects with a normal cTnI level and in patients with an elevated local cTnI level. Healthy subjects as determined by a negative questionnaire and bloodwork underwent 3-minute Infrasensor measurement and levels of high-sensitivity cTnI (hs-cTnI), n-terminal pro-B-type natriuretic peptide (NTproBNP), creatinine, and glycosylated hemoglobin (HbA1c) were evaluated from blood. Patients with elevated cTnI had the same Infrasensor and blood sample measurements. Using a fivefold cross-validation technique, cTnI-based binary classification models that did and did not include age were trained on 80% and validated on 20% of the dataset (n=168; elevated hs-cTnI equally partitioned into five nearly equally-sized subsets ).

resultsOf 840 patients, 727 (87.5%) had normal (nonelevated) cTnI levels while the remaining 113 had elevated cTnI. Median age was 61 years (interquartile range, 52-71 years) for the elevated cohort and 48 years (interquartile range, 32-57 years) for the nonelevated. Overall, 416 (50.5%) were female, with 33 of 113 (29.2%) in the elevated cohort and 383 of 727 (52.7%) in the nonelevated cohort. Overall, the sensitivity, specificity, negative and positive predictive values of the Infrasensor for identifying elevated cTnI were 0.90, 0.70, 0.98 and 0.48, respectively, with a C-statistic of 0.90 (95% confidence interval, 0.89-0.99).

conclusionThe Infrasensor accurately identifies elevated cTnI within 3 minutes of application.

Indexed as

Acute coronary syndromeEmergency medicineMyocardial infarctionTroponin

Identifiers

PMID39237137
PMCPMC12541513

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.