Evidence map›Paper›PMID 39234593›Full record

ArticleJournal of medical signals and sensors2024

Designing an Electrochemical Biosensor Based on Voltammetry for Measurement of Human Chorionic Gonadotropin.

Mohammad Samare-Najaf, Amirreza Dehghanian, Gholamreza Asadikaram, Maryam Mohamadi, Morteza Jafarinia, Amir Savardashtaki, Afrooz Afshari, Sina Vakili

Abstract read
In one paragraph

Article in Journal of medical signals and sensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Mohammad Samare-NajafBlood Transfusion Research Center, Kerman Regional Blood Transfusion Center, High Institute for Research and Education in Transfusion Medicine, Tehran, Iran.
Amirreza DehghanianTrauma Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
Gholamreza AsadikaramApplied Cellular and Molecular Research Center, Kerman University of Medical Sciences, Kerman, Iran.
Maryam MohamadiPistachio Safety Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran.
Morteza JafariniaShiraz Neuroscience Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
Amir SavardashtakiDepartment of Medical Biotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.
Afrooz AfshariDepartment of Pathology, Shiraz University of Medical Sciences, Shiraz, Iran.
Sina VakiliInfertility Research Centre, Shiraz University of Medical Sciences, Shiraz, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Human chorionic gonadotropin (hCG) is a polypeptide hormone synthesized during pregnancy and is also upregulated in some pathologic conditions such as certain tumors. Its measurement is essential for diagnosing pregnancy and malignancies. Despite numerous attempts to introduce an accurate method capable of detecting hCG levels, several limitations are found in previous techniques. This study aimed to address the limitations of current hCG assay methods by designing an electrochemical biosensor based on voltammetry for the rapid, selective, inexpensive, and sensitive measurement of hCG levels. Methods: A carbon paste electrode was prepared and functionalized by para-aminobenzoic acid. The primary anti-β-hCG monoclonal antibody was immobilized on the electrode surface by activating the carboxyl groups with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide solutions. The study also involved optimizing parameters such as the time for primary antibody fixation, the time for hCG attachment, and the pH of the hydrogen peroxide solution to maximize the biosensor response. Different concentrations of hCG hormone were prepared and loaded on the electrode surface, the secondary antibody labeled with HRP enzyme was applied, thionine in phosphate-buffered saline solution was placed on the electrode surface, and the differential pulse electrical signal was recorded. Results: The linear range ranged from 5 to 100 mIU/ml, and the limit of detection was calculated as 0.11 mIU. The relative standard deviation was 3% and 2% for five repeated measurements of commercial standard samples with concentrations of 2 and 20 mIU/mL, respectively. The percent recovery was obtained from 98.3% to 101.5%. Conclusion: The sensor represents a promising advancement in hCG level measurement, offering a potential solution to overcome the existing limitations in current diagnostic strategies. Simple and inexpensive design, detecting hCG in its important clinical range during early pregnancy, and successful measurement of hCG in real serum samples are the advantages of this sensor.

Indexed as

Biosensorelectrochemistryvoltammetryβ-human chorionic gonadotropin

Identifiers

PMID39234593
PMCPMC11373787

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.