Evidence map›Paper›PMID 39234130›Full record

ArticleNational journal of maxillofacial surgery

The surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™.

Neha Sah, Rohit Punga, Ajay Kumar, Peeyush Shivhare, Akhilesh Kumar Singh, Sonam Sah, Amlendu Shekhar

Registry-linked trialAbstract read
In one paragraph

Article in National journal of maxillofacial surgery. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07686913 (A Randomized Prospective Trial Comparing Steri-Strip Application Versus Standard Wound Closure for Cesarean Section Incisions), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07686913 narecruitingnot on this map

A Randomized Prospective Trial Comparing Steri-Strip Application Versus Standard Wound Closure for Cesarean Section Incisions

TypeinterventionalSponsorRiverside University Health System Medical CenterRan2026 to 2027Enrolled610ConditionsCesarean Section, Surgical Site Infection, Wound Dehiscence, SeromaArmsSteri-Strip™ Skin Closures, Standard Cesarean Wound Closure
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Neha SahDepartment of Oral and Maxillofacial Surgery, Dental College Azamgarh, Azamgarh, Uttar Pradesh, India.
Rohit PungaDepartment of Maxillofacial Surgery, School of Dental Sciences (SDS), Sharda University, Greater Noida, Uttar Pradesh, India.
Ajay KumarOral Medicine and Radiology, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India.
Peeyush ShivhareDepartment of Dentistry, AIIMS, Patna, Bihar, India.
Akhilesh Kumar SinghDepartment of Oral & Maxillofacial Surgery, Faculty of Dental Sciences, IMS, BHU, Varanasi, Uttar Pradesh, India.
Sonam SahDepartment of Conservative Dentistry and Endodontics, Kalka Dental College, Ghaziabad, Uttar Pradesh, India.
Amlendu ShekharOral Medicine and Radiology, Faculty of Dental Sciences, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Cosmesis is the primary concern for the patient undergoing facial surgery and there are numbers of well proven materials that are available such as adhesive tapes, subcuticular suture, skin adhesive or glue to achieve better cosmesis. The objective of our study was to assess the surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™. Method: The present prospective study was conducted in 20 patients. Patients were divided into two groups. After subcutaneous closure of wounds, either Dermabond™ or Steri-Strip™ was placed. The patients were assessed for wound complication (erythema, tenderness, dehiscence or any discharge), scar hypertrophy and cosmetic appearance also time consumed in surgical skin closure was evaluated. Wound assessment, scar hypertrophy and cosmetic appearance were assessed by using Chi-square test. Time closure was assessed by using Mann-whitney U test. Result: Twenty patients belonging to all age group were included in study. Ten patients undergone closure with Dermabond™ and ten with Steri-Strips™. Assessment of wound complications, cosmetic appearance and scar hypertrophy was done. There was no significant difference found between both the groups, but 2 patients had fair cosmetic outcomes at one month and 1 patient had fair scar hypertrophy at 6 month. However, excellent cosmetic outcome in terms of scar hypertrophy at 6 month was significantly more among group II. Conclusion: Octyl-2-cyanoacrylate (Dermabond™) and Steri-Strip™ provide similar outcomes in terms of wound complications. Cosmetic outcomes in terms of scar hypertrophy with steri-strip wound closure seem to be better and more economical.

Indexed as

Dermabondsteri-striptissue adhesivewound closure

Identifiers

PMID39234130
PMCPMC11371292

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.