Evidence map›Paper›PMID 39231836›Full record

ArticleInternational orthopaedics2024

The effect of humeral tray thickness on glenohumeral loads in a reverse shoulder 'smart' implant.

Alexandre Caubère, Stella Rutigliano, Samuel Bourdon, John Erickson, Moreno Morelli, Moby Parsons, Lionel Neyton, Marc-Olivier Gauci

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alexandre CaubèreDepartment of Orthopaedic surgery and Traumatology, Military Hospital Sainte-Anne, 2, Bd Sainte Anne BP600, Toulon, 83800, France. alexandre.caubere@hotmail.fr.ORCID 0000-0002-5222-4546
Stella RutiglianoStatera Medical Inc, Montreal, QC, Canada.
Samuel BourdonStatera Medical Inc, Montreal, QC, Canada.
John EricksonOverlook Medical Center, Summit, NJ, USA.
Moreno MorelliDepartment of Orthopaedic Surgery, St Mary's hospital, McGill Medical University, Montreal, QC, Canada.
Moby ParsonsThe Knee, Hip and Shoulder Center, New Hampshire, USA.
Lionel NeytonRamsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
Marc-Olivier GauciUniversitary Insitute of Locomotion and Sport, Pasteur II Hospital, Nice, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study was to observe the effects of changing humeral tray thickness on the resultant of intraoperative glenohumeral joint loads using a load-sensing system (LSS).

methodsAn rTSA was performed on fresh frozen full-body cadaver shoulders by using an internal proprietary LSS on the humeral side. The glenohumeral loads (Newtons) and the direction of the resultant force applied on the implant were recorded during four standard positions (External rotation, Extension, Abduction, Flexion) and three "complex" positions of Activity Daily Life ("behind back", "overhead reach" and "across chest"). For each position, the thickness was increased from 0 to 6 mm in a continuous fashion using the adjustment feature of the humeral system. Each manoeuvre was repeated three times.

resultsAll shoulder positions showed a high repeatability of the glenohumeral load magnitude measured with an intra-class correlation coefficient of over 0.9. For each position, we observed a strong but no linear correlation between humeral tray thickness and joint loads. It was a cubical correlation (r

conclusionThis study provides further insight into the effects of humeral implant thickness on rTSA glenohumeral joint loads during different positions of the arm. Data obtained using this type of device could guide surgeons in finding the proper implant balance during rTSA.

Indexed as

Arthroplasty, Replacement, ShoulderCadaverHumerusShoulder JointShoulder ProsthesisAgedAged, 80 and overBiomechanical PhenomenaFemaleHumansMaleMiddle AgedProsthesis DesignRange of Motion, ArticularWeight-BearingBiomechanical studyGlenohumeral joint loadsReverse total shoulder arthroplastySensor technologySoft tissue tension

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked