Evidence map›Paper›PMID 39230993›Full record

ArticleInvestigative ophthalmology & visual science2024

Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation.

Royston K Y Tan, Gim Yew Ng, Tin A Tun, Fabian A Braeu, Monisha E Nongpiur, Tin Aung, Michaël J A Girard

Abstract read
In one paragraph

Article in Investigative ophthalmology & visual science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Circadian IOP Rhythm in Rats Is Driven by Neural Signals From the Brain.Investigative ophthalmology & visual science · 2026
    Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Royston K Y TanSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Gim Yew NgDepartment of Biomedical Engineering, NUS College of Design and Engineering, National University of Singapore, Singapore.
Tin A TunSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Fabian A BraeuSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Monisha E NongpiurSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Tin AungSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Michaël J A GirardSingapore Eye Research Institute, Singapore National Eye Centre, Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To use finite element (FE) analysis to assess what morphologic and biomechanical factors of the iris and anterior chamber are more likely to influence angle narrowing during pupil dilation. Methods: The study consisted of 1344 FE models comprising the cornea, sclera, lens, and iris to simulate pupil dilation. For each model, we varied the following parameters: anterior chamber depth (ACD = 2-4 mm) and anterior chamber width (ACW = 10-12 mm), iris convexity (IC = 0-0.3 mm), iris thickness (IT = 0.3-0.5 mm), stiffness (E = 4-24 kPa), and Poisson's ratio (v = 0-0.3). We evaluated the change in (△∠) and the final dilated angles (∠f) from baseline to dilation for each parameter. Results: The final dilated angles decreased with a smaller ACD (∠f = 53.4° ± 12.3° to 21.3° ± 14.9°), smaller ACW (∠f = 48.2° ± 13.5° to 26.2° ± 18.2°), larger IT (∠f = 52.6° ± 12.3° to 24.4° ± 15.1°), larger IC (∠f = 45.0° ± 19.2° to 33.9° ± 16.5°), larger E (∠f = 40.3° ± 17.3° to 37.4° ± 19.2°), and larger v (∠f = 42.7° ± 17.7° to 34.2° ± 18.1°). The change in angles increased with larger ACD (△∠ = 9.37° ± 11.1° to 15.4° ± 9.3°), smaller ACW (△∠ = 7.4° ± 6.8° to 16.4° ± 11.5°), larger IT (△∠ = 5.3° ± 7.1° to 19.3° ± 10.2°), smaller IC (△∠ = 5.4° ± 8.2° to 19.5° ± 10.2°), larger E (△∠ = 10.9° ± 12.2° to 13.1° ± 8.8°), and larger v (△∠ = 8.1° ± 9.4° to 16.6° ± 10.4°). Conclusions: The morphology of the iris (IT and IC) and its innate biomechanical behavior (E and v) were crucial in influencing the way the iris deformed during dilation, and angle closure was further exacerbated by decreased anterior chamber biometry (ACD and ACW).

Indexed as

Finite Element AnalysisIrisPupilAnterior ChamberBiomechanical PhenomenaCorneaGlaucoma, Angle-ClosureHumansIntraocular PressureSclera

Identifiers

PMID39230993
PMCPMC11379082

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.