ArticleCombinatorial chemistry & high throughput screening2025
Establishment of LC-MS/MS Methodology for the Determination of Rapamycin Concentration in Rat Whole Blood.
Article in Combinatorial chemistry & high throughput screening, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
backgroundThe establishment and validation of methods for testing biological samples are crucial steps in pharmacokinetic studies. Currently, several methodological reports have been published on the detection of rapamycin plasma concentrations.
objectiveThe objective of this study was to explore an effective method for detecting rapamycin in rat whole blood biological samples.
methodIn this study, we designed a rapid, sensitive, and specific liquid chromatograph-mass spectrometer/mass spectrometer (LC-MS/MS) methodology for detecting rapamycin in rat whole blood biological samples. We comprehensively validated the specificity, linear range, lower limit of quantification (LLOQ), precision, accuracy, recovery, and stability of this method.
resultsThe findings of this study confirmed the successful implementation of LC-MS/MS for the detection of rapamycin, demonstrating its sensitivity, specificity, and reliability in quantitative analysis. This method ensures the accuracy and reliability of subsequent study data through our validated LC-MS/MS approach.
conclusionThe results demonstrated the successful implementation of an LC-MS/MS method for sensitive, specific, and reliable quantitative analysis of rapamycin in rat whole blood samples. This method ensures the accuracy and reliability of subsequent study data. SIGNIFICANCE: The importance of this study lies in the successful establishment of a rapid, sensitive, and specific LC-MS/MS method for detecting rapamycin concentration in rat whole blood, ensuring the accuracy and reliability of subsequent research data. This provides a crucial tool and foundation for further understanding the metabolism and pharmacological effects of rapamycin