ArticleInternational journal of sports physical therapy2024

Validity, Agreement and Reliability of the ForceFrame Dynamometer in Patients with Anterior Cruciate Ligament Injury.

Kamilla Arp, Thomas Frydendal, Troels Kjeldsen, Ulrik Dalgas, Signe Timm, Bjarke Viberg, Kim Ingwersen, Claus Varnum

Abstract read
In one paragraph

Article in International journal of sports physical therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. MERItestJournal of experimental orthopaedics · 2026
    Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Kamilla ArpDepartment of Orthopaedic Surgery Lillebaelt Hospital.
Thomas FrydendalDepartment of Orthopedic Surgery Aarhus University Hospital.
Troels KjeldsenDepartment of Orthopedic Surgery Aarhus University Hospital.
Ulrik DalgasExercise Biology, Department of Public Health Aarhus University.
Signe TimmDepartment of Orthopedic Surgery Lillebaelt Hospital.
Bjarke VibergOrthopaedic Surgery and Traumatology Odense University Hospital.
Kim IngwersenDepartment of Physio- and Occupational therapy Lillebaelt Hospital.
Claus VarnumDepartment of Regional Health Research University of Southern Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Restoring maximal muscle strength of the knee extensors (KE) and knee flexors (KF) following anterior cruciate ligament (ACL) injury and ACL reconstruction is of great importance to reduce the re-injury rate after ACL reconstruction and to reduce the risk of knee osteoarthritis. Therefore, it is essential that clinicians and healthcare providers use valid and reliable measures to assess knee muscle strength to ensure a safe return to sport. Purpose: To evaluate the reliability (test-retest reliability, inter-tester reliability and test-retest agreement) and validity (concurrent validity, convergent validity and ForceFrame (FF) vs. isokinetic dynamometer (ID) agreement) of the ForceFrame (FF) dynamometer during isometric testing of the knee extensors and flexors. Study Design: Cross-sectional study. Material and Methods: Twenty-seven participants with ACL injury or reconstruction were recruited for participation in this study. maximal voluntary isometric contration (MVIC) of the knee extensors and flexors was tested on two separate days. Day one included validity assessments with FF, a gold-standard ID and a handheld dynamometer (HHD). Day two included reliability assessments with FF performed by two assessors. Main outcome measures were day-to-day test-retest reliability and agreement and inter-tester reliability of FF, and concurrent validity (FF vs. an ID and a HHD). Reliability was tested as test-retest and inter-tester reliability using interclass correlation coefficient (ICC), while agreement was tested using Bland & Altman plots with limits of agreement (LOA), standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity between FF, ID, and HHD was assessed using Pearson's correlations and mean difference was evaluated by Bland & Altman plots. Results: Twenty-seven participants (10 females, 17 males) with a median age of 25 years (range 19-60) were included in this study. There was a good day-to-day test-retest reliability for MVIC of KE (ICC=0.77, CI95:0.48-0.90) and KF (ICC=0.83, CI95:0.61-0.92) and excellent inter-tester reliability for MVIC of KE (ICC=0.97, CI95:0.94-0.98) and KF (ICC=0.93, 95CI:0.85-0.97). Standard error of measurement (SEM) was 8% and 9%, while the smallest detectable change (SDC) was 22% and 27% for KE and KF, respectively. FF showed fair concurrent validity compared to ID for KE (r=0.56), poor concurrent validity for knee flexors (KF (r=0.24) and compared to HHD a moderate correlation for KE (r=0.74) and poor correlation for KF (r=0.12). Bland & Altman plots between FF and the ID showed a mean difference of -0.51 Nm/kg for KE and -0.32Nm/kg for KF. Conclusions: FF can be used to obtain reliable and valid results to assess MVIC of the KE, but not the KF. It should be noted that absolute results produced by the FF may be considered an underestimation of actual MVIC. The test position to assess KF in FF does not appear to be optimal, and different test-positions may be considered. Level of evidence: Level 3.

Indexed as

ACLkneemaximal muscle testingvalidation