Evidence map›Paper›PMID 39228660›Full record

ArticleFrontiers in cardiovascular medicine2024

Hemodynamics in the treatment of pseudoaneurysm caused by extreme constriction of aortic arch with coated stent.

Lanlan Li, Yiwei Wang, Ping Jin, Tingting Yang, Guangyu Zhu, Yuxi Li, Jiayou Tang, Yang Liu, Jian Yang

Registry-linked trialAbstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02917980 (Multicenter Registry Study of Surgery and Transcatheter Intervention for Structural Heart Diseases), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02917980 completednot on this map

Multicenter Registry Study of Surgery and Transcatheter Intervention for Structural Heart Diseases

Typeobservational_patient_registrySponsorXijing HospitalRan2016 to 2022Enrolled883ConditionsData Collecting and Analyzing of Different Treatment of Structural Heart Diseases
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lanlan Li *Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Yiwei Wang *Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Ping Jin *Department of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Tingting YangSchool of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Guangyu ZhuSchool of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, China.
Yuxi LiDepartment of Ultrasound Medicine, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Jiayou TangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Yang LiuDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.
Jian YangDepartment of Cardiovascular Surgery, Xijing Hospital, Air Force Medical University, Xi'an, Shaanxi, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: To evaluate the changes in distal vascular morphology and hemodynamics in patients with extremely severe aortic coarctation (CoA) after covered palliative (CP) stent dilation with different surgical strategies. Materials and methods: Perioperative computed tomography angiography and digital subtraction angiography were utilized to construct three aortic models with varying stenosis rates and one follow-up model in a patient with extremely severe CoA. The models included: an idealized non-stenosed model (A: 0%), a model post initial stent deployment (B: 28%), a model post balloon expansion (C: 39%), and a model 18 months after post-balloon expansion (D: 39%). Consistent boundary conditions were applied to all models, and hemodynamic simulation was conducted using the pure fluid method. Results: The narrowest and distal diameter of the stent increased by 34.71% and 59.29%, respectively, from model B to C. Additionally, the distal diameter of the stent increased by -13.80% and +43.68% compared to the descending aorta diameter, respectively. Furthermore, the ellipticity of the maximum cross-section of the aneurysm region in model A to D continued to increase. The oscillatory shear index at the stenosis to the region of the aneurysm were found to be higher in Models A and B, and lower in Models C and D. At the moment of maximum flow velocity, the blood flow distribution in models A and B was more uniform in the widest section of the blood vessels at the distal end of the stenosis, whereas models C and D exhibited disturbed blood flow with more than 2 eddy currents. The time-averaged wall shear stress (TAWSS) decreased in the distal and basal aneurysms, while it significantly increased at the step position. The aneurysmal region exhibited an endothelial cell activation potential value lower than 0.4 Pa Conclusion: In patients with extremely severe CoA, it is crucial to ensure that the expanded diameter at both ends of the CP stent does not exceed the native vascular diameter during deployment. Our simulation results demonstrate that overdilation leads to a decrease in the TAWSS above the injured vessel, creating an abnormal hemodynamic environment that may contribute to the development and enlargement of false aneurysms in the early postoperative period. Clinical Trial Registration: ClinicalTrials.gov, (NCT02917980).

Indexed as

aortic pseudoaneurysmballoon-expandable stentcoarctation of aortahemodynamicssurgical strategy

Identifiers

PMID39228660
PMCPMC11368758

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials